B&C TU7685 Sludge Concentration (SS) Monitor Installation and Operation Manual
This installation and operation manual covers the B&C TU7685 sludge concentration (SS) monitor together with the TU8182 immersion sensor. The document is published by Shanghai Anbi Environmental Protection Equipment Co., Ltd. (www.absh.cn). It describes the measuring principle, the measuring ranges, the panel-mount dimensions, the sensor installation, the terminal wiring, and the configuration settings that are made with the MODE, CAL, ENT and arrow keys.
The TU7685 is a microprocessor-based instrument that uses an infrared light scattering method; the sensor light source is an LED diode. It offers two banks and four ranges (0-9, 0-999, 0-99 and 0-9999 mg/l) selectable in units of NTU, mg/l or ppm, a 0-20 mA or 4-20 mA analog output, two SPDT control relays, an SPST alarm relay and an SPST cleaning relay. The manual walks through the configuration menu step by step and explains the main displays and the AUTO/MAN operating modes. This manual is written in Chinese.
B&C TU7685 specifications
| Measuring principle | Infrared light scattering method with LED light source |
|---|---|
| Measuring ranges | Two banks, four ranges: 0-9, 0-999, 0-99 and 0-9999 mg/l |
| Measuring units | NTU, mg/l, ppm |
| Power supply | 220 V / 50 Hz |
| Monitor dimensions | 96 × 96 × 155 mm |
| Panel cutout | 91.5 × 91.5 mm |
| Analog output | 0-20 mA or 4-20 mA |
| Response time, large signal change | 5-220 s, factory setting 40 s |
| Control relays | Two SPDT control relays |
| Sensor cable | 7.5 m, 7-core cable supplied with the TU8182 sensor |
Source: B&C TU7685 Sludge Concentration (SS) Monitor Installation and Operation Manual
All B&C TU7685 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How does the TU7685 measure sludge concentration?
It uses an infrared light scattering method; the sensor contains an LED infrared light source, a light signal detector, a lens condition detector and a preamplifier.
From: B&C TU7685 Sludge Concentration (SS) Monitor Installation and Operation Manual
What measuring ranges and units are available?
There are two banks with four ranges: 0-9 and 0-999 mg/l, or 0-99 and 0-9999 mg/l, with units selectable as NTU, mg/l or ppm.
From: B&C TU7685 Sludge Concentration (SS) Monitor Installation and Operation Manual
What is the power requirement for the TU7685 monitor?
The TU7685 monitor requires a power supply of 220V/50Hz.
From: B&C TU7685 Sludge Concentration Monitor Installation and Usage Manual
What are the available measurement ranges for the TU7685?
The monitor offers two ranges: 0-9 mg/l, 0-999 mg/l, 0-99 mg/l, and 0-9999 mg/l.
From: B&C TU7685 Sludge Concentration Monitor Installation and Usage Manual