The Premier External TD Installation Manual INS352-3 provides instructions on how to install and use the Premier External TD.
This is the installation manual for the Premier External TD external detector, document number INS352-3, supplied by Texecom Ltd in the UK. It walks through opening the unit, choosing a mounting location, mounting the detector on a wall or pole, wiring the terminal block and setting the jumpers.
The manual also covers PIR range adjustment, the coverage area and walk-testing, the auxiliary input for directional detection, and the technical and physical specifications of the detector, including its relay outputs, IP65 protection and operating temperatures.
| Mounting Height | 1.0 - 1.4m (1.2m nominal) |
|---|---|
| Supply Voltage | 9-16 V DC |
| Current Drain (typical) | 28mA |
| Detection Method | Dual, non-overlapping, digital PIR |
| Range | 12m max., adjustable to 8m, 5m and 2m |
| Alarm Output | NC/NO selectable relay, 50V DC, 100mA, 18Ω |
| Environmental Protection | IP65 |
| Operating Temperature | -35°C (-31°F) to +60°C (+140°F) |
| Weight | 550g (20oz) approx. |
| Warranty | 2 year replacement warranty |
Mount the unit at a height of 1.0 - 1.4m, measured to the middle of the unit, with 1.2m as the nominal height.
It is powered from 9-16 V DC connected to the 12V and 0V terminals.
With the separately available pole mount kit the unit can be fitted to poles with an outside diameter of 20 - 57mm.
Rotate the circular section on the bottom of the head unit until the desired range is shown in the window, and always select the lowest range possible to reduce false alarms.