The Premier Elite 8XP expander is only compatible with the Premier Elite range of control panels. Expanders can be connected serially (daisy chain), in parallel (star) or any combination of the two. During installation, the cover needs to be removed and the expander should be mounted using appropriate screws. It is recommended to completely power down the system before wiring the expander using 4-core cable.
The document provides instructions for installing the Premier Elite 8XP expander, which is compatible with the Premier Elite range of control panels. It details how to mount the unit using countersunk screws and explains wiring configurations including daisy chain (serial), star (parallel), or a combination of both. The guide specifies connecting the device using 4-core cable for power and data transmission.
| Operating Voltage | 10 -14VDC |
|---|---|
| Current Consumption | <120mA |
| Network Cable Length (Daisy) | up to 250m |
| Network Cable Length (Star) | 100m |
| Zones | 8 fully programmable |
| Outputs | 1 - 8: 100mA switched - ve |
| Loudspeaker Output Impedance | Minimum impedance 8Ω |
| Operating Temperature | -10°C to +50 °C |
When set to Daisy mode, expanders can be connected up to 250m apart.
When set to Star mode, the network cabling must not exceed 100m between devices.
It is strongly recommended to use 6 or 8-core cable, though standard 7/0.2 alarm cable can be used.