Nexans MILLITEMP CDFR-003 Thermostat User Manual and Installation Instructions

The MILLITEMP™ CDFR-003 is a programmable thermostat that can control electric floor heating cables in the temperature range of 5-40°C (standard). It has two modes: constant temperature mode and event mode.


Nexans MILLITEMP CDFR-003 Thermostat User Manual and Installation Instructions - cover page
Brand
Nexans
Category
Temperature monitor
Document type
User Manual
Language
SV
Pages
26
File format
PDF
File size
6.3 MB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
FD48564A441E9D640F09B131E23AFB30

About this manual

The Nexans MILLITEMP CDFR-003 is a programmable thermostat for controlling electric floor heating cables in the 5–40 °C range. It automatically regulates room or floor temperature and can run in constant-temperature mode or event mode. It has a built-in room sensor and is supplied with an external floor sensor; a combined mode can use both sensors, with the floor sensor limiting floor temperature.

The document is a Swedish user manual and installation instruction. It covers the product description, technical data, display symbols, first start-up, operating modes, viewing measured sensor values, changing settings, error messages, resetting, and installation. Installation instructions include terminal connections for the heating cable, supply, and floor sensor. This manual is written in Swedish.

What's inside

  • Product description and application
  • Technical data
  • Display symbols
  • First start-up
  • Thermostat operation
  • Constant temperature mode
  • Event mode
  • Changing settings
  • Error messages
  • Installation instructions

Specifications

Rated voltage230 V~
Power consumptionLess than 2 W
Maximum load16 A, about 3600 W at rated voltage
Temperature range+5 °C to +40 °C (standard)
Dimensions84 x 84 x 40 mm (25 mm recess)
Protection classIP 21
Floor sensor cable length3 m
Connection cable cross-section0.5 mm² to 2.5 mm²
Maximum number of heating cables3
Sensor elementNTC
DisplayLCD with blue backlight

Frequently asked questions

What does the CDFR-003 control?

It controls electric floor heating cables in the 5–40 °C range and automatically regulates room or floor temperature.

What is the maximum load of the thermostat?

It is 16 A, approximately 3600 W at rated voltage.

Where is the external floor sensor connected?

If used, the floor sensor is connected to terminals 1 and 2.

Are settings kept after a power failure?

Yes, the thermostat remembers settings after a power failure, with EEPROM backup and no time limit.