This document is an installation manual for the Tarka (PL) series, which are PCB mountable and intended for use within other equipment or enclosures.
This manual (Part No. 17300) contains installation and operation instructions for the Tarka (PL) series DC-DC converters, which are designed to be PCB mounted and used within other equipment or enclosures. It includes general safety instructions, fuse specifications, and input and output ratings for each model.
It covers the PL10S-05, PL10S-12 and PL15S-05 models, with input voltage ranges of 3-5.5 V, 5-13 V and 3.3-5.5 V and maximum output currents of 10 A or 15 A. The manual also states maximum component temperatures to be monitored, test requirements based on the 60950-1 safety standards, and the model designation scheme.
| Maximum ambient temperature | 85°C |
|---|---|
| Fuse, PL10S-05 | External ceramic fuse, 250 V min, HBC T20 A maximum |
| Fuse, PL10S-12 | External ceramic fuse, 250 V min, HBC T12.5 A maximum |
| Input, PL10S-05 | 3-5.5 V, max 8.6 A |
| Input, PL10S-12 | 5-13 V, max 7.5 A |
| Input, PL15S-05 | 3.3-5.5 V, max 12.9 A |
| Output, PL10S-05 | 0.9-2 V at 10 A max |
| Output, PL10S-12 | 0.9-3.3 V at 10 A max |
| Output, PL15S-05 | 0.9-2.5 V at 15 A max |
| XL1 max temperature, PL10S-05 | 115°C (output inductor windings) |
An external ceramic fuse rated 250 V minimum, HBC T20 A maximum.
The maximum permitted ambient temperature is 85°C.
Tests must follow UL60950-1, CSA 22.2 No. 60950-1, EN60950-1 and IEC60950-1 Clause 4.5.
PL stands for Point of Load.