TDK-Lambda Tarka PL Series DC-DC Converter Installation Manual

This document is an installation manual for the Tarka (PL) series, which are PCB mountable and intended for use within other equipment or enclosures.


TDK-Lambda Tarka PL Series DC-DC Converter Installation Manual - cover page
Brand
TDK-Lambda
Category
DC/DC Converters
Document type
Installation Guide
Language
English
Pages
4
File format
PDF
File size
435 KB
Published
06 November, 2023
Updated
06 November, 2023
MD5 checksum
71C1400D8193C4F3835B893245F6C964

About this manual

This manual (Part No. 17300) contains installation and operation instructions for the Tarka (PL) series DC-DC converters, which are designed to be PCB mounted and used within other equipment or enclosures. It includes general safety instructions, fuse specifications, and input and output ratings for each model.

It covers the PL10S-05, PL10S-12 and PL15S-05 models, with input voltage ranges of 3-5.5 V, 5-13 V and 3.3-5.5 V and maximum output currents of 10 A or 15 A. The manual also states maximum component temperatures to be monitored, test requirements based on the 60950-1 safety standards, and the model designation scheme.

What's inside

  • General Safety Instructions
  • Fusing
  • Input
  • Output
  • Safety Agency Approvals
  • Ratings & Limitations
  • Components to be Monitored

Specifications

Maximum ambient temperature85°C
Fuse, PL10S-05External ceramic fuse, 250 V min, HBC T20 A maximum
Fuse, PL10S-12External ceramic fuse, 250 V min, HBC T12.5 A maximum
Input, PL10S-053-5.5 V, max 8.6 A
Input, PL10S-125-13 V, max 7.5 A
Input, PL15S-053.3-5.5 V, max 12.9 A
Output, PL10S-050.9-2 V at 10 A max
Output, PL10S-120.9-3.3 V at 10 A max
Output, PL15S-050.9-2.5 V at 15 A max
XL1 max temperature, PL10S-05115°C (output inductor windings)

Frequently asked questions

What fuse is required for the PL10S-05?

An external ceramic fuse rated 250 V minimum, HBC T20 A maximum.

What is the maximum ambient temperature for the Tarka series?

The maximum permitted ambient temperature is 85°C.

Which safety standards apply to component temperature testing?

Tests must follow UL60950-1, CSA 22.2 No. 60950-1, EN60950-1 and IEC60950-1 Clause 4.5.

What does PL stand for in the model name?

PL stands for Point of Load.