Kohler K582 23 HP Engine Operating and Maintenance Instructions

Kohler engines are durable and long-lasting, with parts made from precision-formulated cast iron that can be re-bored, extending the life of the engine.


Kohler K582 23 HP Engine Operating and Maintenance Instructions - cover page
Brand
Kohler
Category
Motor
Document type
User Manual
Language
English
Pages
15
File format
PDF
File size
3 MB
Published
06 November, 2023
Updated
06 November, 2023
MD5 checksum
C23C7934B8C1724A8F8C91FA813D455F

About this manual

This document gives operating and maintenance instructions for the Kohler K582 (23 hp) engine. It identifies the engine as a four-cycle, twin-cylinder, air-cooled design and includes safety information, oil and fuel recommendations, engine identification numbers, and operating instructions.

The operating section includes a pre-start checklist, cold weather starting hints, starting and stopping procedures, and battery information. Safety warnings cover explosive fuel, rotating parts, hot parts, electrical shock, accidental starts, carbon monoxide, explosive battery gas, and California Proposition 65.

What's inside

  • Safety Information
  • Oil Recommendations
  • Fuel Recommendations
  • Engine Identification Numbers
  • Operating Instructions
  • Pre-Start Checklist
  • Cold Weather Starting Hints
  • Starting
  • Stopping
  • Battery

Specifications

ModelK582 (23 hP)
Engine typeFour-cycle, twin-cylinder, air-cooled
Oil service classAPI service class SG or SH
Oil recommendationStraight 30-weight (Kohler Magnum) oil
Fuel octane87 or higher by pump sticker; 90 minimum by Research method
Approved gasohol blendUp to 10% ethyl alcohol and 90% unleaded gasoline by volume
Approved MTBE blendUp to 15% MTBE by volume
Battery12 volt
Starter cranking limitNo more than 10 seconds at a time

Frequently asked questions

What engine model does this manual cover?

It covers the Kohler K582 (23 hp) engine.

What fuel should I use in the K582 engine?

Use clean, fresh unleaded gasoline with a pump sticker octane rating of 87 or higher; by the Research method, use 90 octane minimum.

How long can I crank the starter?

Do not crank continuously for more than 10 seconds at a time; allow a 60 second cool down period between starting attempts.

What should I do before servicing the engine to prevent accidental starting?

Disconnect and ground the spark plug lead before servicing.

Download PDF (3 MB)