WIDEPLUS WP Series Dry and Wet Bulb Humidity Printing Instrument User Manual

This is the user manual for the Dry and Wet Ball Humidity Printer. It mainly introduces the product introduction, technical parameters, operating instructions, instrument calibration method, printing function, wiring diagram and other content.


WIDEPLUS WP Series Dry and Wet Bulb Humidity Printing Instrument User Manual - cover page
Brand
Wide Plus
Category
Temperature monitor
Document type
User Manual
Language
Chinese
Pages
8
File format
PDF
File size
182 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
B912F22ADAC95428DD0E3A249BFE5433

About this manual

The WIDEPLUS WP series is a dry and wet bulb humidity printing instrument with two control channels, intended for temperature and humidity measurement and control in high-temperature, high-humidity environments. It uses two three-wire Pt100 resistance inputs as dry-bulb and wet-bulb probes and calculates relative humidity indirectly from the two temperatures, atmospheric pressure and the instrument coefficient, and it can print measured values or print at set time intervals. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Main Technical Specifications
  • Operating Guide
  • Instrument Calibration Method
  • Printing Function
  • Wiring Diagram
  • WP Series Model Selection Table
  • Saturated Vapor Pressure of Water Table
  • Humidity Coefficient Calculation Software
  • Standard Documents and Accessories

Specifications

Accuracy±0.5%FS ±1 digit
Operating conditions0 to 50 °C, relative humidity ≤85%
Temperature inputTwo three-wire Pt100 resistance inputs
Relay output contact ratingAC220V/5A (resistive load)
Power supplyAC/DC 90 to 260 V, ≤15 W
WeightApprox. 1000 g
Dimensions144×144×180 mm, panel cutout 138×138 mm
Humidity accuracy after calibrationBetter than 1 %RH
Measurement range0 to 100 °C and 0 to 100 %RH

Frequently asked questions

What inputs does the instrument use for dry and wet bulb measurement?

It uses two three-wire Pt100 resistance inputs, so the dry-bulb temperature and the humidity can be measured at the same time with the wet-bulb method.

How is the relative humidity determined?

The humidity is obtained indirectly by measuring the dry-bulb and wet-bulb temperatures and calculating the relative humidity from them.

What maintenance does the wet-bulb method need?

Only regular addition of water to the wet bulb and replacement of the wet-bulb gauze is required.

How are measured values printed?

Pressing the key prints the current measured value of each channel in a TIMEPRINT line with date, time and the dry-bulb, wet-bulb and relative humidity values.

Download PDF (182 KB)