This manual introduces the safety precautions, prevention of electric shock, fire prevention and breakage prevention for AC motor drive products.
This user manual covers the i Series AC motor drives, including models IDW200-751 (0.75 kW) and IDT400-401 (0.4 kW). It provides safety precautions, installation, wiring, and operating instructions for use with three-phase induction AC motors.
The manual also lists electrical specifications, environmental conditions, standard connection diagrams, terminal assignments, parameter settings, protection functions, and troubleshooting guidance for the drives. This manual is written in Chinese.
| Applicable motor capacity (IDW200-751) | 0.75 kW |
|---|---|
| Applicable motor capacity (IDT400-401) | 0.4 kW |
| Input voltage | Single-phase or three-phase AC 200–240 V |
| Permissible voltage fluctuation | +10%, -10% |
| Power frequency | 50 Hz / 60 Hz (±5%) |
| Rated capacity (IDW200-751) | 1.3 kVA |
| Rated capacity (IDT400-401) | 0.9 kVA |
| Mass (IDW200-751) | 690 g |
| Mass (IDT400-401) | 460 g |
| Drive method | V/f control (PWM control) |
| Overload current rating | 150% (1 min) |
| Protection structure | IP20 |
| Cooling method | Natural cooling |
| Ambient temperature | -10 °C to 50 °C |
| Altitude | 1000 m or less |
Three-phase induction AC motors.
150% of rated current for one minute.
IP20.