KAWASAKI MACHINERY ROBOT CONTROLLER F SERIES INSTALLATION AND CONNECTION MANUAL
This manual covers installation and connection work for arc welding robots controlled by Kawasaki F Series robot controllers. It addresses safety precautions, the work flow for installing and connecting an arc welding robot, wire feeder installation, torch mounting, and single-wire power cable connection.
It also covers mounting points for the arc welding interface board, connection wiring to a welding machine (DM-350), the arc welding machine interface board, and replacement and readjustment of a damaged torch. This manual is written in Chinese.
| Minimum clearance from high-voltage lines | At least 1 m |
|---|---|
| Leakage breaker sensitivity | 100 mA or more |
| Robot primary power switch isolation | Independent from the welding machine |
It describes installation and connection work for arc welding robots controlled by F Series controllers.
Lock the breaker and put up a tag; an inspector may also be assigned in front of the breaker until all connections are complete.
Keep them at least 1 m away.
Repair or replace the torch and adjust the mounting.