VIVOTEK IP8172/72P Fixed Network Camera Quick Installation Guide

This manual describes how to install and configure the IP8172/72P fixed network camera.


VIVOTEK IP8172/72P Fixed Network Camera Quick Installation Guide - cover page
Brand
Vivotek
Category
Other
Document type
Other
Language
English
Pages
12
File format
PDF
File size
4.1 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
990407A758935073552D9249AE877970

About this manual

This guide explains how to mount and connect the VIVOTEK IP8172/72P fixed network camera, including lens installation, general and PoE network connections, and IP address assignment using Installation Wizard 2.

It also covers ready-to-use adjustments such as zoom and focus, fine-tuning the CS-mount adapter ring, and lens dimension requirements for compatible lenses.

What's inside

  • Warning Before Installation
  • Package Contents
  • Physical Description
  • Mounting the Lens to the Camera
  • General Connection
  • Assigning an IP Address
  • Ready to Use
  • Fine-tune the CS-Mount

Specifications

VideoFull HD
Focus assistFocus Assist
PowerPoE-compliant
Lens mountCS-mount
Flange back lengthLonger than 12.5 mm
Screw mount lengthShorter than 5.2 mm
Lens edge to front panel distanceLonger than 0.5 mm

Frequently asked questions

How do I assign an IP address to the camera?

Install Installation Wizard 2 from the Software Utility directory on the software CD, then double-click the MAC address matching the camera label to open a browser management session.

Can I install a P-Iris lens on the IP8172?

No. Do not install a P-Iris lens to the IP8172, and do not install a DC-Iris lens to the IP8172P, because the voltages supplied to the modules are different.

What should I do if I cannot get sharp images with a particular lens?

Fine-tune the CS-mount adapter ring using the supplied L-type hex key wrench and a removal tool, then tighten the lens retention screw.

What lens dimensions are required for the IP8172/72P?

The flange back length must be longer than 12.5 mm, the screw mount must be shorter than 5.2 mm, and the distance between the lens edge and front panel must be longer than 0.5 mm.