RAE Systems ToxiRAE 3 Single-Gas Detector User Guide

ToxiRAE 3 User Guide


RAE Systems ToxiRAE 3 Single-Gas Detector User Guide - cover page
Brand
RAE Systems
Category
detectors
Document type
User Manual
Language
Japanese
Pages
42
File format
PDF
File size
1.1 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
D49BCD75D37C3D1F00087E886CCAA2EA

About this manual

The ToxiRAE 3 is a programmable single-gas detector from RAE Systems designed for exposure monitoring of people working in hazardous environments. This Japanese user guide covers general information, specifications, the user interface, startup and shutdown, alarm testing, battery alarms, operation in normal and programming modes, bump testing and calibration with the calibration adapter or AutoRAE Lite, diagnostic mode, alarm signal summary, maintenance, troubleshooting, technical support and regulatory information.

Stated specifications include dimensions of 8.6 x 5.5 x 2.0 cm, a weight of 99 g including the battery, a user-replaceable 2/3 AA lithium battery, a 95 dB buzzer at 30 cm with red flashing LED and vibration alarm, an IP-67 rating, an operating temperature of -20°C to +60°C, and a T90 response time under 12 seconds. Standard configurations include CO (low), CO (high) and H2S sensors, and calibration is a two-point zero and span procedure. This manual is written in Japanese.

What's inside

  • General Information
  • Specifications
  • Overview and User Interface
  • Startup and Shutdown
  • Alarm Test and Battery Alarms
  • Operation Modes
  • Bump Test and Calibration
  • Diagnostic Mode
  • Maintenance and Troubleshooting
  • Appendix A: Regulatory Information

Specifications

Dimensions3.4 in (L) x 2.2 in (W) x 0.8 in (H) / 8.6 cm x 5.5 cm x 2.0 cm
Weight3.5 oz (99 g) including battery
BatteryUser-replaceable 2/3 AA high-capacity lithium battery
Alarm95 dB buzzer at 30 cm with red flashing LED; vibration alarm; 6-LED alarm display
Operating time2 years (when IR communication is not used)
H2S range and resolution0 to 100 ppm, 0.1 ppm resolution
CO range and resolution0 to 500 ppm, 1 ppm resolution; also 0 to 1999 ppm, 1 ppm resolution
Response timeT90 < 12 seconds
Calibration2-point calibration, zero and span
IP ratingIP-67
Operating temperature-20°C to +60°C continuous
Humidity0 to 95% relative humidity, non-condensing

Frequently asked questions

How do I turn on the ToxiRAE 3?

Press and hold the [MODE] key for 3 seconds.

What battery does the ToxiRAE 3 use?

A RAE Systems lithium battery, part number 500-0076-100 (3.6V, 1650 mAh, 2/3AA size), which the user can replace in a safe area.

How loud is the ToxiRAE 3 alarm?

The buzzer produces 95 dB at a distance of 30 cm, together with a red flashing LED and a vibration alarm.

Download PDF (1.1 MB)

More RAE Systems Manuals