This manual covers the RAE Systems SP-1102, a fixed-mount, explosion-proof combustible gas detector using catalytic combustion technology.
The RAE Systems SP-1102 is a fixed-mount, explosion-proof combustible gas detector designed for continuous operation in hazardous environments. It features a catalytic combustion sensor and offers multiple signal outputs, including 4-20mA and relay contacts, suitable for integration with PLC/DCS systems or standalone control. This manual is written in Chinese.
| Detection Principle | Catalytic Combustion |
|---|---|
| Sampling Method | Diffusion |
| Operating Power | 10~30VDC |
| Maximum Power | 150mA@24VDC |
| Output Signal | 4~20mA, adjustable |
| Load Impedance | 600Ω |
| Other Output | Alarm Relay 30VDC 2A (Passive) |
| Detection Accuracy | ±2%F.S. |
| Response Time (T90) | <15s |
| Protection Rating | IP65 |
| Operating Temperature | -40℃ ~+70℃ |
| Explosion Proof Certification | Ex d II CT6 |
The SP-1102 uses catalytic combustion for detection.
The device operates on a DC power supply between 10V and 30V.
The detection accuracy is ±2% of Full Scale.