WindObserver IS is an intrinsically safe ultrasonic anemometer that transmits wind speed and direction data to the control room via a wireless communications interface in accordance with UK CAA CAP 437. It is suited to offshore oil production platforms, support tankers, drilling platforms, onshore petrochemical plants and other hazardous petrochemical environments.
This four-page leaflet from Gill Instruments describes the WindObserver IS, an intrinsically safe ultrasonic anemometer for hazardous areas. It presents key features, the split between the hazardous-area anemometer and the non-hazardous-area power and communications interface, and full technical specifications for the anemometer, the Mains Voltage Power & Communications Interface (PCI) and the Low Voltage Power & Communications Interface (LVPCI).
The leaflet states that the system suits offshore oil production platforms, support tankers, drilling platforms, onshore petrochemical plants and other hazardous petrochemical environments, and provides wind speed and direction data for offshore meteorological observations in accordance with UK CAA CAP 437. ATEX and IECEx certification is listed along with certification numbers, codes and approval standards, and the text notes the system requires no regular maintenance beyond a visual check.
| Wind speed range | 0 - 75 m/s |
|---|---|
| Wind speed accuracy | 2% at 12 m/s |
| Wind speed resolution | 0.01 m/s |
| Starting threshold | 0.01 m/s |
| Direction range | 0 - 359° |
| Direction accuracy | ± 4° |
| Anemometer power | 6V - 12VDC, 30 mA peak (from PCI or LVPCI) |
| Digital output | RS422, full duplex to PCI or LVPCI |
| Baud rates | 1200, 2400, 4800, 9600, 19200 |
| Output rate | 1 Hz, 2 Hz or 4 Hz |
| Averaging | 0 - 3600s |
| Anemometer construction | Stainless Steel 316 |
| Anemometer weight | 1.9 kg |
| Anemometer size | 380mm x 210mm |
| Anemometer moisture protection | IP66 (NEMA4X) |
| Ambient operating temperature | -30°C to +70°C |
| Storage temperature | -50°C to +75°C |
| Humidity | 0% to 100% RH |
| Anemometer certification number | IECEx SIR 15.0013; Sira 15ATEX2014 |
| PCI AC supply input | 100 Vac - 120 Vac, 10 VA for the 115V switch position; 200 Vac - 250 Vac, 10 VA for the 230V switch position |
| PCI weight | 9.5 Kg |
| PCI size | 230 x 325 x 175mm |
| LVPCI DC supply input | 9V to 30V dc at 200mA max |
| LVPCI construction | Fibox Euronord Polyester |
| LVPCI size | 260 x 160 x 93mm |
| LVPCI weight | 2.4 Kg |
| LVPCI moisture protection | IP54 |
The anemometer is ATEX and IECEx certified, with certification numbers IECEx SIR 15.0013 and Sira 15ATEX2014. The certification allows worldwide deployment without local recertification.
The WindObserver IS is certified as intrinsically safe for use in the hazardous area, while the associated power and communications interface sits in the non-hazardous area.
The system requires no regular maintenance beyond a visual check.
The anemometer can be fed from a Mains Voltage Power & Communications Interface (PCI) or a Low Voltage Power & Communications Interface (LVPCI).