Gill Instruments WindObserver IS Intrinsically Safe Anemometer Product Leaflet

WindObserver IS is an intrinsically safe ultrasonic anemometer that transmits wind speed and direction data to the control room via a wireless communications interface in accordance with UK CAA CAP 437. It is suited to offshore oil production platforms, support tankers, drilling platforms, onshore petrochemical plants and other hazardous petrochemical environments.


Gill Instruments WindObserver IS Intrinsically Safe Anemometer Product Leaflet - cover page
Brand
Gill Instruments
Category
sensor
Document type
Product Leaflet
Language
English
Pages
4
File format
PDF
File size
491 KB
Published
02 November, 2023
Updated
02 November, 2023
MD5 checksum
17CE4E4586359602E7D7829FEDD9BD36

About this manual

This four-page leaflet from Gill Instruments describes the WindObserver IS, an intrinsically safe ultrasonic anemometer for hazardous areas. It presents key features, the split between the hazardous-area anemometer and the non-hazardous-area power and communications interface, and full technical specifications for the anemometer, the Mains Voltage Power & Communications Interface (PCI) and the Low Voltage Power & Communications Interface (LVPCI).

The leaflet states that the system suits offshore oil production platforms, support tankers, drilling platforms, onshore petrochemical plants and other hazardous petrochemical environments, and provides wind speed and direction data for offshore meteorological observations in accordance with UK CAA CAP 437. ATEX and IECEx certification is listed along with certification numbers, codes and approval standards, and the text notes the system requires no regular maintenance beyond a visual check.

What's inside

  • Key Features
  • Hazardous Area / Non-Hazardous Area system layout
  • Anemometer power requirement, wind speed and direction
  • Digital output and measurement
  • Anemometer mechanical and environmental data
  • Mains Voltage Power & Communications Interface (PCI)
  • Low Voltage Power & Communications Interface (LVPCI)
  • Certifications and approvals
  • Inputs and outputs of the interfaces

Specifications

Wind speed range0 - 75 m/s
Wind speed accuracy2% at 12 m/s
Wind speed resolution0.01 m/s
Starting threshold0.01 m/s
Direction range0 - 359°
Direction accuracy± 4°
Anemometer power6V - 12VDC, 30 mA peak (from PCI or LVPCI)
Digital outputRS422, full duplex to PCI or LVPCI
Baud rates1200, 2400, 4800, 9600, 19200
Output rate1 Hz, 2 Hz or 4 Hz
Averaging0 - 3600s
Anemometer constructionStainless Steel 316
Anemometer weight1.9 kg
Anemometer size380mm x 210mm
Anemometer moisture protectionIP66 (NEMA4X)
Ambient operating temperature-30°C to +70°C
Storage temperature-50°C to +75°C
Humidity0% to 100% RH
Anemometer certification numberIECEx SIR 15.0013; Sira 15ATEX2014
PCI AC supply input100 Vac - 120 Vac, 10 VA for the 115V switch position; 200 Vac - 250 Vac, 10 VA for the 230V switch position
PCI weight9.5 Kg
PCI size230 x 325 x 175mm
LVPCI DC supply input9V to 30V dc at 200mA max
LVPCI constructionFibox Euronord Polyester
LVPCI size260 x 160 x 93mm
LVPCI weight2.4 Kg
LVPCI moisture protectionIP54

Frequently asked questions

What certifications does the WindObserver IS have?

The anemometer is ATEX and IECEx certified, with certification numbers IECEx SIR 15.0013 and Sira 15ATEX2014. The certification allows worldwide deployment without local recertification.

Where are the anemometer and its interface installed?

The WindObserver IS is certified as intrinsically safe for use in the hazardous area, while the associated power and communications interface sits in the non-hazardous area.

What maintenance does the system need?

The system requires no regular maintenance beyond a visual check.

What power supply options are available?

The anemometer can be fed from a Mains Voltage Power & Communications Interface (PCI) or a Low Voltage Power & Communications Interface (LVPCI).