This manual introduces the composition, parameters, sensors, power supply voltage, power supply connector, and firmware upgrade of the MetPak base station
This manual provides instructions for the MetPak Base Station, a professional multi-sensor instrument designed to measure essential weather parameters. It covers various models including the MetPak, MetPak RG, and MetPak Pro, detailing their part numbers, compatible sensors, and derived parameters such as wind speed, direction, temperature, humidity, and barometric pressure. The device integrates data from multiple sensors into a single combined data string.
| Compatible Wind Sensors | Gill 2 axis (WindSonic or WindObserver) or 3 axis (WindMaster or WindMaster Pro) |
|---|---|
| Communication Protocols | RS232/RS422/RS485, MODBUS RTU/ASCII, SDI-12 |
| Mounting Clamp Diameter | 30mm to 58mm |
| Included Cable Length | 10 Metre |
The station is compatible with Gill 2 axis (WindSonic or WindObserver) or 3 axis (WindMaster or WindMaster Pro) wind speed and direction sensors.
It can be configured for digital ASCII RS232/RS422/RS485, digital MODBUS RTU/ASCII, and SDI-12 outputs.
The mounting clamp attaches to any vertical pipe up from 30mm to 58mm diameter.