This manual introduces the installation procedure for the intrinsically safe wind speed monitor
This manual provides installation instructions for the Gill Instruments Intrinsically Safe WindObserver ultrasonic anemometer system, designed for use in hazardous areas (Zone 0, 1, and 2). The document covers two main system kits: Part 1360-PK-022 (Mains Power Supply) and Part 1360-PK-060 (Low Voltage Power Supply). It details pre-installation requirements, system diagrams, and specific guidelines for mounting, cabling, and alignment.
| I.S. Rating | ATEX European and IECEx International (For use in Zone 0, 1 and 2 Areas) |
|---|---|
| Wind Speed Range | 0 - 75m/s |
| Wind Direction Range | 0 - 359° |
| Power Requirement | 6V-12VDC, 30mA peak |
| Ambient Operating temperature | -30°C to +70°C |
| Moisture protection | IP66 (NEMA4X) |
No, the anemometer has no customer serviceable parts and requires no calibration or maintenance.
The units are user selectable and include m/s, Knots, MPH, KPH, and ft/min.
Yes, the output message format can be configured in Polar, UV (2-axis), NMEA, tunnel, or Binary.