This manual contains instructions for installing, operating, and maintaining the Dresser ES3 Electronic TC
The Dresser ES3 is an electronic temperature compensator with a mechanical counter for Series B meter bodies. It combines electronic temperature compensation with the Series 3 non-compensated mechanical index and registers displaced volume in actual cubic feet on an eight-digit odometer.
The manual covers mechanical design, odometer reading, meter start-up, LCD display, mounting, pulse output connections, operation modes, maintenance, battery and temperature probe replacement, proving with the Dresser Model 5 Transfer Prover, firmware upgrades, and specifications. The stated operating temperature range is -40°F to 140°F (-40°C to 60°C).
| Operating Temperature Range | -40°F to 140°F (-40°C to 60°C) |
|---|---|
| Average Battery Life | 20 years |
| Data Logging Capacity | 150 days of hourly data in non-volatile memory |
| Temperature Probe | PT 1000 |
| Pulse Outputs | Two configurable Form A pulse outputs |
| Odometer | Eight-digit |
| Volume Registration | Actual cubic feet (ACF) |
The stated temperature operating range is -40°F to 140°F (-40°C to 60°C).
It uses a PT 1000 temperature probe.
It stores 150 days of hourly data in non-volatile memory.
It provides two configurable Form A pulse outputs for AMR endpoints.