This manual introduces the features and usage methods of the Dresser Series D Meter Models D800 and D1000, including performance characteristics, receiving, use, installation, operation and maintenance.
This manual provides step-by-step instructions for installing, operating, and maintaining Dresser Series D800 and D1000 diaphragm replacement meters. It covers meter setup, calibration, troubleshooting, and maintenance procedures including lubrication, cleaning, and cartridge replacement. The meters are designed for commercial natural gas applications and feature a compact, oil-free design with rotary positive displacement technology. They offer accurate, non-adjustable measurement and support multiple testing methods including differential pressure and proving with external provers.
The manual also includes sections on firmware upgrades, temperature and flow rate measurement, fault and alarm handling, and logging features. Safety precautions and handling guidelines are provided for installation and maintenance, including warnings about operating temperatures and potential hazards.
| Accuracy | Permanent and non-adjustable |
|---|---|
| Start Rate | 0.30 ACFH |
| Ramp to Accuracy | 8 ACFH |
| Maximum Capacity | 1700 ACFH |
| Maximum Allowable Operating Pressure | 25psig |
| Temperature Operating Range | -40°F to +140°F (-40°C to +60°C) |
| Pulse Output | Two scalable pulse output signals |
The meter is rated at 25psig maximum allowable operating pressure (MAOP).
The meter operates between -40°F to +140°F (-40°C to +60°C).
The meter can store up to 150 days of hourly logs in non-volatile memory.
The meter is designed for clean, dry natural gas and other non-corrosive gases.