This manual introduces the basic information of IMC/W2 gas volume corrector, including models, configurations, specifications, dimensions, interfaces, installation, safety requirements, etc.
The Dresser IMC/W2 is an electronic counter and volume corrector designed for natural gas solutions. It combines high-resolution volume sensing via a Wiegand sensor with live pressure and temperature measurement to calculate corrected volume. The unit is intrinsically safe for hazardous areas and utilizes E2PROM memory to store data and audit logs without backup batteries. It can be configured via a serial port using the Micro Corrector User Terminal software.
| Pressure Port Size | 1/8" NPT male fitting |
|---|---|
| Temperature Accuracy | better than 0.5°C (0.9°F) |
| Operating Temperature Range | -40°F to +140°F (-40°C to +60°C) |
| Pulse Output Capability | sinking 10mA |
| Voltage Withstanding | up to 15 Volts |
The IMC/W2 measures live pressure and temperature, while the IMC/W2 T-Only measures live temperature and requires a fixed line pressure value.
It is set up and calibrated from a laptop computer via the serial port using Dresser's Micro Corrector User Terminal software.
It utilizes E2PROM memory to store setup data and audit logs during periods of no power.