Bacharach STINGER High Performance Oilless Commercial Refrigerant Recovery Unit User Manual

This manual introduces the use of STINGER high-performance oilless recovery unit.


Bacharach STINGER High Performance Oilless Commercial Refrigerant Recovery Unit User Manual - cover page
Brand
Bacharach
Category
Other products
Document type
User Manual
Language
English
Pages
36
File format
PDF
File size
2.8 MB
Published
01 November, 2023
Updated
01 November, 2023
MD5 checksum
9049C1FB843450AE8C66C948A16C7495

About this manual

This manual is for the Bacharach STINGER high-performance oilless refrigerant recovery unit. It covers safety precautions, specifications, feature descriptions, recovery and charging operations, purging, DOT recovery cylinder safety, recovery tips, troubleshooting, a schematic diagram, parts lists, and a declaration of conformity.

The STINGER is compatible with many refrigerants and is rated for 120 V or 230 V single-phase power, with a 3/4 HP oilless compressor, two cooling fans, and high- and low-side pressure ratings of 550 psi and 450 psi.

What's inside

  • Safety
  • Specifications
  • Descriptions of Features
  • Vapor/Liquid Recovery Operations
  • Standard Recovery Hose Connections
  • Liquid Push-Pull Recovery Operations
  • Liquid-Pull Recovery / Charging Method
  • R-410A Recovery – Special Notes
  • Purging the STINGER
  • DOT Recovery Cylinder Safety

Specifications

Compatible refrigerantsR-12, R-22, R-114, R-134a, R-401A, R-401B, R-401C, R-402A, R-402B, R-404A, R-406A, R-407A, R-407B, R-407C, R-407D, R-408A, R-409A, R-410A, R-411A, R-411B, R-412A, R-500, R-502, R-507, R-509
Compressor3/4 HP high performance oilless
CoolingTwo cooling fans
ProtectionHigh pressure cutoff at 550 psi; compressor protected by circuit breakers and internal compressor thermal sensor; optional 80% tank full shutoff kit (P/N 2090-0091)
Pressure ratingsLow side design pressure 450 psi; high side design pressure 550 psi
Operating temperature range32 to 104 °F (0 to 40 °C)
Size (L x W x H)17 in x 9.5 in x 11 in (43.2 cm x 24.1 cm x 27.9 cm)
Weight28 lbs (12.7 kg)
CertificationComplies with UL1963 (not evaluated for automotive use)
R-22 liquid recovery rate3.53 lb/min (1.60 kg/min)
R-410A liquid recovery rate3.02 lb/min (1.37 kg/min)

Frequently asked questions

What is the warranty period for the STINGER?

Bacharach warrants the product for 1 year from the date of purchase, and the motor brushes carry an extended warranty of 5 years.

What recovery cylinder should be used for R-410A?

Only cylinders rated at 400 psi with the relief valve setting at 600 psi should be used for R-410A.

What extension cord should be used for a 50-foot run?

A 14 gauge cord with a maximum length of 50 feet should be used.

What ventilation is required when using the STINGER?

It should be used in a location with mechanical ventilation providing at least 4 air changes per hour, or located at least 18 inches above the floor.