TDK-Lambda GH1-60kW Programmable DC Power Supplies use EtherCAT technology to provide 0–600V / 0–500A of power and support multiple control methods, including LAN, USB, RS-232, and RS-485 interfaces.
The document is the EtherCAT manual supplement IA761-04-05C for TDK-Lambda programmable DC power supplies in the GH1kW through GSPS60kW series, including the 1U, 2U, 3U, and 20U models listed on the cover. It covers the EtherCAT option, control methods, specifications, and communication setup.
The supplement explains how to select EtherCAT, LAN, local, serial, or analog control, view MAC addresses, reset EtherCAT, and establish TwinCAT 3 communication. It also documents the EtherCAT data structure, SDO/PDO mapping, command timing, and multi power supply and parallel connection.
| Ethernet compliance | IEEE 802.3, Auto-MDIX |
|---|---|
| Ethernet speed and duplex | 100Base-T, full duplex |
| EtherCAT protocols | CoE (CANopen over EtherCAT) |
| Firmware file access | FoE, for firmware update only |
| EtherCAT connectors | Two Ethernet RJ-45 connectors, standard 8-pin jack |
| EtherCAT indicators | RUN LED, ERROR LED, and two port link/activity indicators |
| MAC address | EtherCAT has a unique MAC address |
| Typical PDO cycle | About 20 mSec |
| Protocol security | All protocols except EtherCAT (CoE and FoE) are blocked |
| Compliance | UL, IEC, TUV, CE, ROHS |
It allows the user to remotely program, measure, and check the status of the power supply using EtherCAT (CANopen over EtherCAT).
The rear panel has two Ethernet RJ-45 connectors for EtherCAT IN and OUT chain connection.
The typical PDO cycle is about 20 milliseconds.
No; EtherCAT disables the serial and LAN communication ports.