Nokeval 2012 Input Card User Manual

2012 is an input card for measuring mA or V signal or a potentiometer. The card can be plugged into the 2000 panel meter series, 2800 field meter series, 910E/920E large panel meter series, or 575F/1000F/1100F/ 1800F large field display series. The reading is displayed with six digits, if desired. Fixed trailing zeros are available. The card features a freely adjustable lowpass filter, hold function, and tare function. An external switch or relay contact can be used to trigger the hold and tare functions. 2012 supports several 2000 series auxiliary cards: an analog output card, a serial communications card, and two- or three- relay alarm cards. If the same device is equipped with two 2012 input cards, the combination is called 2212. It is possible to calculate a simple mathematical operation among the channels.


Nokeval 2012 Input Card User Manual - cover page
Brand
Nokeval
Category
Other Electronics
Document type
User Manual
Language
English
Pages
30
File format
PDF
File size
1.7 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
947DA3AD5F930FBA50B3C3106607A7E8

About this manual

2012 is an input card for measuring an mA or V signal or a potentiometer. It can be plugged into the 2000 panel meter series, 2800 field meter series, 910E/920E large panel meter series, or 575F/1000F/1100F/1800F large field display series. The reading can be displayed with six digits, and fixed trailing zeros are available. The card includes a freely adjustable lowpass filter, hold function, and tare function; an external switch or relay contact can trigger hold and tare. It supports 2000 series auxiliary cards such as an analog output card, a serial communications card, and two- or three-relay alarm cards. If one device is equipped with two 2012 input cards, the combination is called 2212, and a simple mathematical operation can be calculated among the channels.

This manual covers connections, installation for the 2000, 2800, 910E/920E, and 1000F/1100F/1800F series, the user interface, the 2012 input card, and the 2000-OUT, 2000-RS, and 2000-RELx auxiliary cards, followed by technical specifications. Configuration can be done with the front or back panel display and buttons, via an RS-232 or RS-485 bus when a serial communications card is installed, or via the POL connector on the input card in slot A when no serial communications card is installed.

What's inside

  • Introduction
  • Connections
  • Installing 2000
  • Installing 2800
  • Installing 910E/920E
  • Installing 1000F/1100F/1800F
  • User interface
  • Input card 2012-IN
  • Output card 2000-OUT
  • Specifications

Specifications

Galvanic isolationFrom outputs and supply voltage; two input cards share a common ground
ResolutionNot observable (24 bits)
Overvoltage limitNot allowed above 120 VDC or 50 VAC with respect to ground
mA input resistanceApprox. 80 ohm
mA input range0…24 mA or wider
mA thermal drift±100 ppm/°C
V input resistance1.1 Mohm
V input range0…12 V or wider
V thermal drift±100 ppm/°C
Potentiometer resistance100 ohm…10 kohm
Potentiometer thermal drift±150 ppm/°C
Transmitter supply24 V ±20%, max 150 mA
Panel meter supply voltage (230 VAC model)85…260 VAC or VDC
Panel meter supply voltage (24 VDC model)12…32 VDC or 20…28 VAC
Panel meter powerMax 12 W; typ 3 W if transmitter supply not used and input card only
Panel meter protection class2 (reinforced insulation)
Panel meter operating temperature-10…60°C
Panel meter IP classIP65 front panel when gasket supplied is installed
Field meter supply voltage (230 VAC model)85…260 VAC or VDC
Field meter supply voltage (24 VDC model)12…32 VDC or 20…28 VAC
Field meter powerMax 12 W
Field meter protection class2 (reinforced insulation)
Field meter operating temperature-10…60°C
Field meter IP classIP65

Frequently asked questions

What signals can the Nokeval 2012 input card measure?

It measures an mA or V signal or a potentiometer.

Which meter series can the 2012 card be plugged into?

It can be plugged into the 2000 panel meter series, 2800 field meter series, 910E/920E large panel meter series, or 575F/1000F/1100F/1800F large field display series.

What is a device with two 2012 input cards called?

The combination is called 2212.

Can the 2012 card perform calculations between channels?

Yes, a simple mathematical operation can be calculated among the channels.

Download PDF (1.7 MB)

More Nokeval Manuals


View all Nokeval manuals →