This manual introduces the use, installation, electrical connection, troubleshooting and other information of elero 13 109.6401 RevoLine VariEco NHK
This manual provides installation, adjustment, and troubleshooting instructions for the elero 13 109.6401 RevoLine VariEco NHK tubular drive. It covers mechanical limit stops, emergency manual operation, and electrical connections. Safety precautions and technical specifications are included for proper use and maintenance.
The drive is designed for small applications and features a noiseless soft brake up to 20 Nm. Installation requires careful alignment and limit switch adjustment. Emergency crank handle is provided for power failure or mechanical failure. Technical data includes voltage, torque, and dimensions for different models.
| Rated voltage | 1 ~ 230 V |
|---|---|
| Noiseless soft brake | • – – – – – – – – |
| Rated torque | 20 Nm |
| Rated speed | 14 1/min |
| Shaft diameter | 50 mm |
| Protection class | IP44 |
| Limit switch range | 29 revolutions |
| Operating time | 4 min S2 |
| Plug-in connection cable length | 2.0 m |
It allows manual operation of the blind in case of power failure or mechanical failure, but should not be used regularly to avoid damaging the drive.
No, due to feedback voltage from the installed capacitor, never connect several drives in parallel.