Lonhand LH-IO204 / LH-IO204-232 2-Channel Serial Relay User Manual

2 way serial relay instruction manual, introduces the product characteristics, working mode, specification parameters, product size, communication protocol and data format, electrical connection, product maintenance, after-sales service and other contents.


Lonhand LH-IO204 / LH-IO204-232 2-Channel Serial Relay User Manual - cover page
Brand
LonHand
Category
RELAY
Document type
User Manual
Language
Chinese
Pages
30
File format
PDF
File size
1.8 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
105C5224C8F4136FF3C89BD0F002DF92

About this manual

This Chinese manual covers the LH-IO204 and LH-IO204-232 two-channel serial relays from Lonhand, part of the LH-IO series of relay devices that use the standard Modbus-RTU protocol, support RS485/RS232 communication and accept a wide 9-28V DC supply.

The document explains the configurable working modes (normal, pulse on/off, local non-lock, self-lock and interlock linking, and two-unit linking), lists the specifications, and gives the Modbus register and coil address tables with detailed commands. It also includes the DIP-switch and software address settings, input and output wiring diagrams, maintenance and environment notes, a troubleshooting question-and-answer section, and after-sales information. This manual is written in Chinese.

What's inside

  • Product introduction
  • Operating mode description
  • Specifications
  • Product dimensions
  • Communication protocol and data format
  • Modbus register description
  • Electrical wiring
  • Product maintenance
  • Common problems and solutions
  • After-sales service

Specifications

Operating voltage9-28V DC (reverse-connection protected)
Communication interfaceRS485 / RS232
Communication protocolStandard Modbus-RTU
Baud rate2400, 4800, 9600 (default), 19200, 38400, 115200; software configurable
Default communication format9600, n, 8, 1
Slave address0-255; built-in 5-bit address DIP switch sets 1-31, addresses above 31 set by software (RS232 version has no DIP switch)
Power indicator2 red LEDs
DI input voltage (optocoupler isolated)5-24V
Allowable air humidity5-85%RH

Frequently asked questions

What protocol and interfaces does the LH-IO204 relay use?

It is an LH-IO series relay device using the standard Modbus-RTU protocol and supporting RS485/RS232 communication.

What is the default serial setting of the relay module?

9600 baud, no parity, 8 data bits, 1 stop bit; the baud rate and parity can be changed in the PC software.

What supply voltage does the module require?

9-28V DC; the device supports reverse-connection protection.

How do I restore factory settings on a model with DIP switches?

With power on, set all DIP switches to ON, toggle bit5 back and forth six times, then set all switches down; the device can then be reached with the PC software at 9600 baud, address 254.

Download PDF (1.8 MB)