Lonhand LH-IO404 4-Way Serial Relay User Manual

4-way serial relay instruction manual, introduces the product features and characteristics, including working mode, specification parameters, product size, communication protocol and data format, electrical wiring, product maintenance and other contents


Lonhand LH-IO404 4-Way Serial Relay User Manual - cover page
Brand
LonHand
Document type
User Manual
Language
Chinese
Pages
29
File format
PDF
File size
1.9 MB
Published
29 October, 2023
Updated
29 October, 2023
MD5 checksum
08B7F8D63F8B65A4022E77A2F764CD12

About this manual

This manual provides detailed instructions for operating the Lonhand LH-IO404 4-way serial relay, including its various working modes such as normal, flash-open/close, and interlock modes. It also covers technical specifications, wiring diagrams, communication protocols (Modbus-RTU), and troubleshooting tips for common issues.

The device supports RS485/232 communication, operates on 9–28VDC, and is designed for industrial, agricultural, and smart city applications. Maintenance and environmental guidelines are included, along with warranty and support information. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Working Modes
  • Specifications
  • Communication Protocol
  • Wiring Diagrams
  • Maintenance and Troubleshooting
  • After-sales Service

Specifications

Working Voltage9-28VDC (supports reverse polarity protection)
Power Consumption12V: <0.5W idle, <3W full load; 24V: <0.5W idle, <3W full load
Communication InterfaceIsolated RS485
Communication ProtocolStandard Modbus RTU

Frequently asked questions

How do I reset the device to factory settings?

For models with dip switches, power on while setting all switches to ON, toggle bit5 six times (one toggle = one cycle), then set all switches to OFF. Use the upper computer software (9600 baud, address 254) to communicate.

Why does the relay only open but not close?

Check if the slave address is correctly read, verify if the return command is received and correct. If the address read fails or the return command is abnormal, check the communication cable and converter.

Why can't I control the relay using the 485 interface after powering it?

Check if the 485 lines are reversed or if the voltage is within the specified range. Also verify if the slave address is set to 254 and test different baud rates.