This product is a laser PM2.5/10/100 sensor that uses laser scattering principle to obtain the concentration of suspended particulate matter in the air between 0.3 and 10 microns. It uses imported lasers and photosensitive components, with stable and reliable data; it has a built-in fan, digital output, and high integration. It can be widely used in PM2.5 detectors, air purifiers, new air conditioners, TSP monitoring, dust monitoring, road, factory, mine, stone processing plant, building site environment monitoring.
The Lonhand ZZ-SDS011 and SDS198 are laser-scattering particulate matter sensors. ZZ-SDS011 measures PM2.5 and PM10, while SDS198 measures PM100; both provide digital serial output and include a built-in fan.
The manual describes specifications, dimensions, host-computer software setup, debugging, communication protocol and message parsing, installation, maintenance and after-sales service. This manual is written in Chinese.
| Measured parameters (ZZ-SDS011) | PM2.5 and PM10 |
|---|---|
| Measured parameter (SDS198) | PM100 |
| Measurement range (ZZ-SDS011) | PM2.5: 0.0-999.9 μg/m3; PM10: 0-1999.9 μg/m3 |
| Measurement range (SDS198) | PM100: 0-20000 μg/m3 |
| Signal output | TTL, 3.3 V |
| Supply voltage | 5 V (4.7-5.3 V) |
| Power consumption | Greater than 1 W (current greater than 200 mA) |
| Power supply voltage ripple | Less than 20 mV |
| Maximum operating current | 90 mA ±10 mA |
| Sleep current | Less than 4 mA |
| Operating temperature and humidity | -10 to 50 C, less than 70% RH |
| Storage temperature and humidity | -20 to 60 C, less than 90% RH |
| Operating atmospheric pressure | 86-110 kPa |
| Response time | 1 s |
| Serial data output frequency | 1 Hz |
| Minimum resolvable particle size | 0.3 μm (ZZ-SDS011); 1 μm (SDS198) |
| Counting efficiency | 70% at 0.3 μm; 98% at 0.5 μm |
| Relative error (ZZ-SDS011) | ±15% and ±10 μg/m3 maximum at 25 C, 50% RH |
| Relative error (SDS198) | ±20% and ±30 μg/m3 maximum at 25 C, 50% RH |
| Certifications | CE/FCC/RoHS |
| Product dimensions | 71 x 70 x 23 mm |
| Laser diode service life | Up to 8000 hours |
ZZ-SDS011 measures PM2.5 and PM10, while SDS198 measures PM100.
The sensor requires 5 V, within the range of 4.7 to 5.3 V.
The product dimensions are 71 x 70 x 23 mm.
The laser diode service life is up to 8000 hours.