Lonhand ZZ-SDS011 and SDS198 High Precision Laser PM2.5/10 and PM100 Sensor User Manual

This product is a laser PM2.5/10/100 sensor that uses laser scattering principle to obtain the concentration of suspended particulate matter in the air between 0.3 and 10 microns. It uses imported lasers and photosensitive components, with stable and reliable data; it has a built-in fan, digital output, and high integration. It can be widely used in PM2.5 detectors, air purifiers, new air conditioners, TSP monitoring, dust monitoring, road, factory, mine, stone processing plant, building site environment monitoring.


Lonhand ZZ-SDS011 and SDS198 High Precision Laser PM2.5/10 and PM100 Sensor User Manual - cover page
Brand
LonHand
Category
sensor
Document type
User Manual
Language
Chinese
Pages
22
File format
PDF
File size
1.4 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
D53F2C3AFCBADD9D04ABBFFFDBD9E4DC

About this manual

The Lonhand ZZ-SDS011 and SDS198 are laser-scattering particulate matter sensors. ZZ-SDS011 measures PM2.5 and PM10, while SDS198 measures PM100; both provide digital serial output and include a built-in fan.

The manual describes specifications, dimensions, host-computer software setup, debugging, communication protocol and message parsing, installation, maintenance and after-sales service. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Specifications
  • Product Dimensions
  • Host Computer Software
  • Debugging Process
  • Communication Protocol and Message Parsing
  • Installation
  • Product Maintenance
  • After-Sales Service

Specifications

Measured parameters (ZZ-SDS011)PM2.5 and PM10
Measured parameter (SDS198)PM100
Measurement range (ZZ-SDS011)PM2.5: 0.0-999.9 μg/m3; PM10: 0-1999.9 μg/m3
Measurement range (SDS198)PM100: 0-20000 μg/m3
Signal outputTTL, 3.3 V
Supply voltage5 V (4.7-5.3 V)
Power consumptionGreater than 1 W (current greater than 200 mA)
Power supply voltage rippleLess than 20 mV
Maximum operating current90 mA ±10 mA
Sleep currentLess than 4 mA
Operating temperature and humidity-10 to 50 C, less than 70% RH
Storage temperature and humidity-20 to 60 C, less than 90% RH
Operating atmospheric pressure86-110 kPa
Response time1 s
Serial data output frequency1 Hz
Minimum resolvable particle size0.3 μm (ZZ-SDS011); 1 μm (SDS198)
Counting efficiency70% at 0.3 μm; 98% at 0.5 μm
Relative error (ZZ-SDS011)±15% and ±10 μg/m3 maximum at 25 C, 50% RH
Relative error (SDS198)±20% and ±30 μg/m3 maximum at 25 C, 50% RH
CertificationsCE/FCC/RoHS
Product dimensions71 x 70 x 23 mm
Laser diode service lifeUp to 8000 hours

Frequently asked questions

Which particulate matter sizes do the ZZ-SDS011 and SDS198 measure?

ZZ-SDS011 measures PM2.5 and PM10, while SDS198 measures PM100.

What supply voltage does the sensor require?

The sensor requires 5 V, within the range of 4.7 to 5.3 V.

What are the product dimensions?

The product dimensions are 71 x 70 x 23 mm.

How long is the laser diode service life?

The laser diode service life is up to 8000 hours.

Download PDF (1.4 MB)