Barksdale temperature switch products include local mount and remote bulb and capillary models. Local mount switches are installed in the pipe or vessel, while remote models allow the switch enclosure to be placed up to 25 feet from the media. The products are offered in housed, NEMA 4 and/or explosion proof designs with one or two adjustable temperature set points and fixed or adjustable differential.

An ambient compensation device cancels adverse effects of ambient fluctuation; bulb and capillary configurations maintain ±1% of full-scale accuracy in the mid-60% of the adjustable range under extreme ambient changes from -65°F to +165°F, and ±0.5% full scale at constant ambient. The guide also covers differential by switch class, hermetically sealed switches for hostile environments, and AC/DC electrical ratings for models such as MT1H, T2H, T1X, T2X, ML1H, L2H and L1X.

What's inside

  • Sensor Types
  • Local Mount
  • Remote Bulb & Capillary
  • General Data
  • Ambient Temperature Compensation Comparison Curve
  • Differential (Actuation Value, Dead Band, Hysteresis)
  • Hermetically Sealed Switches
  • Electrical Rating
  • AC Ratings
  • DC Ratings

Specifications

Ambient compensation range-65°F to +165°F
Accuracy in mid-60% of adjustable range±1% of full-scale
Accuracy at constant ambient±0.5% full scale
Remote enclosure distanceUp to 25 feet
Standard capillary lengths6 and 12 feet
Extra capillary lengthsUp to 25 feet
Local mount pressure ratingThrough 300 PSI
Available designsHoused, NEMA 4 and/or explosion proof
Temperature set pointsOne or two adjustable
DifferentialFixed or adjustable
Watertight ratingNEMA 4 and 13
Explosion proof ratingNEMA 7 and 9
Hermetically sealed hazardous areaClass I, Division II

Frequently asked questions

How far from the media can a remote bulb switch enclosure be placed?

Up to 25 feet.

Are local mount switches affected by ambient temperature changes?

No; all filling fluid is exposed to the media temperature, so there is no ambient temperature influence on the filling fluid.

What accuracy is maintained at constant ambient temperature?

±0.5% full scale.

What hazardous area requirement do hermetically sealed switches meet?

Class I, Division II hazardous areas.