This document is a user manual for Elan S6, which introduces the functions and usage of the device
This is the Elan System6 (S6) Quick Reference Guide. It explains the power available at each ZONE KEYPAD INPUT RJ45 jack on the S6, lists the current draw of ZPADs, Z025, VSEs and additional IR receivers so the 300mA limit per input is not exceeded, and gives the DIP switch settings for zones 1 through 6. It also notes that when more than one ZPAD is installed in a single zone, the wiring should be paralleled and both ZPADs assigned the same Zone ID.
The guide covers the S6 front panel adjustments and status indicators, keypad input wiring with ELAN keypads, connecting IR receivers and emitters, and connecting multiple keypads in a single zone. A rear panel connections overview lists zone trigger outputs, source status inputs, modular speaker connectors, IR emitter outputs and zone keypad/VIA! inputs, and design notes explain that the internal amplifier is always variable and that RCA preouts are provided for subzone applications.
| Zone keypad input power | 12 VDC at 300 mA per RJ45 jack |
|---|---|
| ZPAD current draw (with IR tube) | 65 mA |
| Z025 current draw | 85 mA |
| VSE current draw | 40 mA |
| Additional IR receiver current draw | 10 mA |
Each ZONE KEYPAD INPUT RJ45 jack on the S6 provides 12VDC at 300mA, so the combined load of connected devices must not exceed 300mA.
A ZPAD with IR tube draws 65mA, a Z025 draws 85mA, a VSE draws 40mA and each additional IR receiver draws 10mA.
All wiring should be paralleled and both ZPADs should be assigned the same Zone ID.
The S6 internal amplifier is always variable, and volume commands are IR controlled, so an IR keypad, VIA! or IR receiver must be connected to each zone input.