This manual provides instructions for installing and using Industrial Ethernet Rail Switch RS20/RS22/RS30/RS32/RS40
This user manual covers installation of the Hirschmann RS20/RS22/RS30/RS32/RS40 family of industrial Ethernet rail switches. It begins with safety instructions, then describes device variants, assembly and start-up, display elements, basic set-up, disassembly and technical data.
The document includes notes on SELV supply circuits, Class 2 wiring for North America, ATEX conditions, PoE power supply units RPS90/48V-LV and RPS90/48V-HV, grounding and ventilation requirements. It also lists technical data and further support contact information.
| Supply voltage connection | SELV circuits according to IEC/EN 60950-1 |
|---|---|
| PoE power supply RPS90/48V-LV input voltage | 18 V DC to 60 V DC |
| PoE power supply RPS90/48V-HV input voltage | 48 V DC to 320 V DC or 90 V AC to 265 V AC |
| North America supply | Class 2 circuits |
| Ground conductor cross-section | at least 1.0 mm² |
| Clearance to ventilation slits | at least 10 cm (3.94 in) |
| Installation position | vertical |
| ATEX enclosure protection | at least IP54 |
The device may only be connected to SELV circuits with the voltage restrictions of IEC/EN 60950-1. For North America, it is intended for use in Class 2 circuits.
The RPS90/48V-HV unit accepts 48 V DC to 320 V DC or 90 V AC to 265 V AC.
The manual says the latest version is available on the Internet at the Hirschmann product site, www.hirschmann-ac.de.
Use a ground conductor with a cross-section of at least 1.0 mm².