This manual introduces the operation method, maintenance and other information of PCB Piezotronics, Inc. RUN DOWN ADAPTOR.
This manual provides instructions for installing and operating the Model 92300-063972 Run Down Adaptor, designed to deliver consistent torque readings with power-driven tools. It covers mounting procedures, operational safety, torque application, and maintenance guidelines, including lubrication and calibration recommendations. The document also includes RoHS compliance information and joint rate characteristics for different torque ranges.
The adaptor is intended for qualified personnel and must be used with proper safety precautions. It reduces torque irregularities and is compatible with torque analyzers. Maintenance involves periodic lubrication and cleaning, with specific guidance for threads and washers. Calibration is recommended annually or after environmental exposure.
| Effective Torque Range | Within specified range for repeatable torque data |
|---|---|
| Free Turns | At least 5 full rotations with less than 5% of nominal torque |
| Hard Joint Rate | Simulated when used below 12% of maximum torque capacity |
| Soft Joint Rate | Achieved when used above 50% of maximum torque capacity |
| Mean Torque | 121.72 lbf.in |
| Standard Deviation | 11.53 lbf.in |
Mount the adaptor in-line between the tool drive and transducer, and secure the transducer on a solid surface or test bench.
Hard joint simulation occurs when used below 12% of its maximum torque capacity.
It is recommended to disassemble, clean, and re-coat the threads with molybdenum grease every 6 months.
The standard deviation is 11.53 lbf.in.