PCB Piezotronics Model 105C12 Subminiature ICP Pressure Sensor Installation and Operating Manual

Installation and operating manual for the PCB Piezotronics Model 105C12 Subminiature ICP pressure sensor, covering setup, calibration, and safety.


PCB Piezotronics Model 105C12 Subminiature ICP Pressure Sensor Installation and Operating Manual - cover page
Brand
PCB Piezotronics
Category
sensor
Document type
User Manual
Language
English
Pages
11
File format
PDF
File size
808 KB
Published
29 October, 2026
Updated
29 October, 2026
MD5 checksum
161CB6A0A034D4D42E87054D0EC38959

About this manual

This document is the Installation and Operating Manual for the PCB Piezotronics Model 105C12 Subminiature ICP pressure sensor. It is designed for measuring dynamic pressures in limited spaces and includes instructions for installation, operation, calibration, and safety considerations. The manual also provides information on warranty, repair procedures, and hazardous material compliance.

What's inside

  • Introduction
  • Description
  • Installation
  • Model 105A
  • Models 105C02, C12 & C22
  • Models 105C03, C13, 23, C33, C43
  • Flash Temperature Protection
  • Recessed Installation
  • Calibration
  • Safety Considerations

Specifications

Full-scale range1000 psi
Sensitivity5 mV/psi
Diaphragm diameter0.099 inch
Mounting thread10-32 mtg thd
Output impedanceless than 100 ohms
Bias voltage+11 volt (nominal)

Frequently asked questions

How often should the sensor be calibrated?

We recommend calibrating on an annual basis, after exposure to any extreme environmental influence, or prior to any critical test.

What is the recommended cable for Model 105C sensors?

Use coaxial 002G10 cable, 5-44 to 10-32 microdot.