Carrier TS1001 Touch Screen Arming Station Installation Manual

This document is the installation manual for the TS1001 Touch Screen Arming Station. It introduces the product's functions and features, installation requirements, installation methods, and operating methods.


Carrier TS1001 Touch Screen Arming Station Installation Manual - cover page
Brand
Carrier
Category
Monitoring Equipment
Document type
Installation Guide
Language
English
Pages
27
File format
PDF
File size
727 KB
Published
28 October, 2023
Updated
28 October, 2023
MD5 checksum
9E84770F437B3CD85CF20C19638E8022

About this manual

The Carrier TS1001 Touch Screen Arming Station is a remote arming station for Challenger security systems. It features a touch screen keypad, beeper, integrated tamper switch, area and system status LEDs, one open collector output, and one egress input. The device supports graphical and classic operating modes.

This installation manual covers mounting, wiring, DIP switch settings, LCD and button brightness adjustment, programming menu options (including egress control, tamper control, scramble keypad, LED configuration), troubleshooting, firmware upgrades, and mounting templates. Specifications include a nominal 13.8 VDC supply (8.5–14 VDC), maximum current draw of 155 mA, operating temperature 0–50°C, and dimensions of 132 × 92 × 22 mm.

What's inside

  • Product overview
  • User interface details
  • Front LED indications
  • Specifications
  • Installing the RAS
  • Mounting the RAS
  • Connecting the RAS
  • Programming RAS menu options
  • Troubleshooting
  • Firmware upgrade procedures

Specifications

Nominal voltage13.8 VDC (8.5 to 14 VDC)
Maximum current consumption155 mA @ 13.8 VDC
Normal current consumption100 mA @ 13.8 VDC
Operating temperature0 to 50°C
Operating humidity0 to 95% noncondensing
Dimensions (W x H x D)132 x 92 x 22 mm

Frequently asked questions

What is the operating voltage range for the TS1001?

The nominal voltage is 13.8 VDC with a range of 8.5 to 14 VDC.

What are the dimensions of the TS1001?

The device measures 132 mm wide, 92 mm high, and 22 mm deep.

How should the touch screen be cleaned?

Breathe on the screen to fog it, then gently wipe with a soft dry cloth; for stubborn marks, moisten the cloth with isopropyl or ethyl alcohol.

What is the maximum current draw of the TS1001?

The maximum current consumption is 155 mA at 13.8 VDC when the touch screen and key illumination are at maximum brightness and all area LEDs are on.