This operator's manual provides information on the basic operation, installation, and maintenance of the INGERSOLL RAND 6661TX-X-C 1-1/2” Non-Metallic Air Operated Double Diaphragm Pump.
The document is the operator's manual for the Ingersoll Rand 6661TX-X-C non-metallic air operated double diaphragm pump, referred to in the text as an ARO diaphragm pump. It lists pump data, model and material options, service kits and a general description, including the pump's pressure differential operation and ball checks.
The safety section covers excessive air pressure, static spark grounding, hazardous pressure, hazardous materials and explosion hazards. It warns that models containing aluminum wetted parts cannot be used with 1,1,1-trichloroethane, methylene chloride or other halogenated hydrocarbon solvents.
| Pump Type | Non-Metallic Air Operated Double Diaphragm |
|---|---|
| Inlet / Outlet | 1-1/2” ANSI Flange |
| Weight, Polypropylene | 62 lbs (28.1 kg) |
| Weight, PVDF (Kynar) | 92 lbs (41.7 kg) |
| Maximum Air Inlet Pressure | 120 psig (8.3 bar) |
| Maximum Outlet Pressure | 120 psig (8.3 bar) |
| Maximum Material Inlet Pressure | 10 psig (0.69 bar) |
| Maximum Flow Rate (flooded inlet) | 100 gpm (378.5 lpm) |
| Maximum Particle Size | 1/4” dia. (6 mm) |
| Maximum Temperature, Polypropylene | 35 ° to 175° F (1.7° to 79° C) |
| Maximum Temperature, PVDF (Kynar) | 10 ° to 200° F (-12° to 93° C) |
| Noise Level @ 70 psig, 60 cpm | 77.7 db(A) |
The maximum air inlet pressure is 120 psig (8.3 bar).
The maximum flow rate is 100 gpm (378.5 lpm).
The maximum particle size is 1/4 in. (6 mm) diameter.
The air section repair kit is 637118-C.