Ingersoll Rand 6661TX-X-C 1-1/2 in Non-Metallic Air Operated Double Diaphragm Pump Operator's Manual

This operator's manual provides information on the basic operation, installation, and maintenance of the INGERSOLL RAND 6661TX-X-C 1-1/2” Non-Metallic Air Operated Double Diaphragm Pump.


Ingersoll Rand 6661TX-X-C 1-1/2 in Non-Metallic Air Operated Double Diaphragm Pump Operator's Manual - cover page
Brand
Ingersoll-Rand
Category
Other
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
687 KB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
CAB6A28EBB79804D32EF3BBA5EF45804

About this manual

The document is the operator's manual for the Ingersoll Rand 6661TX-X-C non-metallic air operated double diaphragm pump, referred to in the text as an ARO diaphragm pump. It lists pump data, model and material options, service kits and a general description, including the pump's pressure differential operation and ball checks.

The safety section covers excessive air pressure, static spark grounding, hazardous pressure, hazardous materials and explosion hazards. It warns that models containing aluminum wetted parts cannot be used with 1,1,1-trichloroethane, methylene chloride or other halogenated hydrocarbon solvents.

What's inside

  • Service Kits
  • Pump Data
  • Model Description Chart
  • General Description
  • Operating and Safety Precautions
  • Excessive Air Pressure
  • Static Spark
  • Hazardous Pressure
  • Hazardous Materials
  • Explosion Hazard

Specifications

Pump TypeNon-Metallic Air Operated Double Diaphragm
Inlet / Outlet1-1/2” ANSI Flange
Weight, Polypropylene62 lbs (28.1 kg)
Weight, PVDF (Kynar)92 lbs (41.7 kg)
Maximum Air Inlet Pressure120 psig (8.3 bar)
Maximum Outlet Pressure120 psig (8.3 bar)
Maximum Material Inlet Pressure10 psig (0.69 bar)
Maximum Flow Rate (flooded inlet)100 gpm (378.5 lpm)
Maximum Particle Size1/4” dia. (6 mm)
Maximum Temperature, Polypropylene35 ° to 175° F (1.7° to 79° C)
Maximum Temperature, PVDF (Kynar)10 ° to 200° F (-12° to 93° C)
Noise Level @ 70 psig, 60 cpm77.7 db(A)

Frequently asked questions

What is the maximum air inlet pressure?

The maximum air inlet pressure is 120 psig (8.3 bar).

What is the maximum flow rate with a flooded inlet?

The maximum flow rate is 100 gpm (378.5 lpm).

What is the maximum particle size the pump can handle?

The maximum particle size is 1/4 in. (6 mm) diameter.

Which service kit is used for the air section?

The air section repair kit is 637118-C.