Ingersoll-Rand Air Balancers Series ZA, EA and BA Maintenance Manual

This document mainly introduces the features and usage methods of Ingersoll-Rand Air Balancers Series ZA, EA and BA (Dwg. MHP2176).


Ingersoll-Rand Air Balancers Series ZA, EA and BA Maintenance Manual - cover page
Brand
Ingersoll-Rand
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
56
File format
PDF
File size
2.7 MB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
3841A767E2BFEA5CCBAEE8B4051501F1

About this manual

This manual provides maintenance and installation instructions for Ingersoll-Rand Air Balancers Series ZA, EA, and BA. It details the product description, including the ball screw and piston mechanism, and specifies that only trained technicians should perform maintenance. The document outlines the use of genuine replacement parts to ensure safety and warranty validity.

What's inside

  • Product Description
  • Specifications
  • Installation
  • Hook Mounted Balancer Installation
  • Trolley Mounted Balancer Installation
  • Rail Mounted Balancer Installation
  • Air System
  • Air Lines
  • Air Line Filter
  • Operational Adjustments

Specifications

Maximum Air Pressure100 psi (6.9 bar)
Air Line Minimum Diameter3/8 in. (10 mm)
Maximum Air Line Length100 ft. (30 m)
Filtration Requirement10 micron

Frequently asked questions

Who is authorized to perform maintenance on this product?

Only Ingersoll Rand trained technicians are allowed to perform maintenance on this product.

What happens if air pressure is reduced below 100 psi?

For every one psi reduction in air pressure, there is a 1% reduction in overall capacity.

Can a lubricator be used with the air supply?

No, do not use a lubricator of any kind as oil will damage internal components.