This manual provides information on operating, installing and maintaining the Ingersoll Rand PD03P-X-X 3/8” DIAPHRAGM PUMP 1:1 RATIO, NON-METALLIC.
The document serves as an operator's manual for the Ingersoll Rand PD03P-X-X series of 3/8" air-operated double diaphragm pumps. These pumps feature a non-metallic construction with various material options compatible with different fluids and temperatures.
Key sections include safety precautions regarding static sparks, hazardous pressure, and materials; general descriptions of the pump's stall-resistant design; operating instructions for flushing and cycling; and maintenance guidelines utilizing specific service kits for air and fluid sections.
| Maximum Air Inlet Pressure | 100 p.s.i.g. (6.9 bar) |
|---|---|
| Maximum Material Inlet Pressure | 10 p.s.i.g. (0.69 bar) |
| Maximum Outlet Pressure | 100 p.s.i.g. (6.9 bar) |
| Air Consumption @ 40 p.s.i. | 1 c.f.m. / gallon |
| Maximum Flow Rate (flooded inlet) | 10.6 g.p.m. |
The maximum air inlet pressure is 100 p.s.i.g. (6.9 bar).
No, there is no lubrication required other than the O-ring lubricant applied during assembly or repair.
A filter capable of filtering out particles larger than 50 microns should be used.