Ingersoll Rand 66615X-X-C Diaphragm Pump Service Manual

Service manual for the Ingersoll Rand 66615X-X-C 1‑1/2" diaphragm pump with operation, safety, parts and troubleshooting information.


Ingersoll Rand 66615X-X-C Diaphragm Pump Service Manual - cover page
Brand
Ingersoll
Document type
Service Manual
Language
Chinese
Pages
8
File format
PDF
File size
860 KB
Updated
06 October, 2026
MD5 checksum
7FAF0186D4081391CCF1957BEC29B3CD

About this manual

This manual provides detailed instructions for operating, installing, maintaining and repairing the 1‑1/2" diaphragm pump model 66615X‑X‑C. It includes safety precautions, parts lists for the fluid and pneumatic sections, and fault diagnosis guidelines.

The document also describes recommended lubrication, grounding procedures, and the use of specific repair service kits to ensure reliable pump performance in industrial applications. This manual is written in Chinese.

What's inside

  • Operation and Safety Precautions
  • General Description
  • Parts List – Fluid Section
  • Parts List – Pneumatic Motor
  • Repair Service Kits
  • Fault Diagnosis

Specifications

Maximum inlet pressure120 psig (8.3 bar)
Maximum outlet pressure120 psig (8.3 bar)
Maximum discharge port size1/4" dia (6.4 mm)

Frequently asked questions

What is the maximum inlet pressure for the pump?

The pump’s maximum inlet pressure is 120 psig (8.3 bar).

How should the pump be grounded for safe operation?

Use the grounding terminal on the pump or the ARO part 66885‑1 grounding tool and connect a minimum 12‑AWG grounding wire to a good earth point.

Which service kit is used for gas‑side repairs?

Service package 637118‑C is the general gas‑side repair kit applicable to all ARO diaphragm pumps of this size.

What lubrication is recommended for O‑rings during re‑assembly?

Apply Key‑Lube grease to all O‑rings and sealing surfaces during re‑assembly.