About this manual

This guide provides step-by-step instructions for installing Swagelok GSI series weir-style diaphragm valves, including diaphragm replacement and travel stop adjustment. Safety precautions are emphasized before any servicing. The document covers storage, drainability, welding, and maintenance procedures. It includes detailed diagrams and torque specifications for proper assembly and sealing.

What's inside

  • Introduction
  • Transportation and Storage
  • Drainability
  • Welding
  • Diaphragm Maintenance
  • Replacing the Diaphragm
  • Travel Stop Adjustment

Frequently asked questions

What steps must be taken before servicing an installed valve?

You must depressurize the system, cycle the valve, and purge the valve before performing any service.

How should the valve be mounted to ensure proper drainability?

Mount the valve so that the hash marks are at the 12 o'clock position and ensure the piping is appropriately sloped.

What tool is required to remove the handwheel lock screw?

A 4 mm hex wrench is required to remove the handwheel lock screw and washer.