This document provides installation instructions for GSI series weir-style diaphragm valves, including installation, disassembly, and maintenance.
This guide provides step-by-step instructions for installing Swagelok GSI series weir-style diaphragm valves, including diaphragm replacement and travel stop adjustment. Safety precautions are emphasized before any servicing. The document covers storage, drainability, welding, and maintenance procedures. It includes detailed diagrams and torque specifications for proper assembly and sealing.
You must depressurize the system, cycle the valve, and purge the valve before performing any service.
Mount the valve so that the hash marks are at the 12 o'clock position and ensure the piping is appropriately sloped.
A 4 mm hex wrench is required to remove the handwheel lock screw and washer.