Pepperl+Fuchs Tab-Ex® 03 D2 Ex-Safety Manual

This is a safety manual that introduces the use, precautions, maintenance methods, etc. of Tab-Ex® 03 D2


Pepperl+Fuchs Tab-Ex® 03 D2 Ex-Safety Manual - cover page
Brand
pepperl+Fuchs
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
16
File format
PDF
File size
406 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
22523CC9492751B14DA2ACFE76A62A2C

About this manual

This safety manual provides critical safety instructions for using the Tab-Ex® 03 D2 tablet in hazardous areas. It details safety precautions, warnings, and operational limits including temperature ranges and approved battery types. The device must be installed with proper protective covers before entering hazardous zones. Repairs must be performed by authorized service centers. Cleaning and storage must follow specified guidelines to maintain safety compliance.

The manual also includes technical specifications such as certification details (Ex-Marking, Ambient Temperature), applicable standards (UL121201, CSA C22.2 No 213), and connection rules for hazardous and non-hazardous locations. Specific warnings prohibit charging, data transfer, or opening the device in hazardous areas. Only approved accessories and battery types are permitted.

What's inside

  • Application
  • Safety Precautions
  • Faults and Damage
  • Ex-Data
  • Warnings
  • Safety Instructions
  • Repair
  • Cleaning, Maintenance and Storage
  • Warranty and Liability
  • Connections

Specifications

Ex-MarkingClass I, Division 2 Groups A, B, C, D T5; Class II, Division 2 Groups F, G T100°C; Class III
Ambient Temperature-20 °C ≤ Ta ≤ +55 °C
Approved BatterySamsung EB-BT575BBE
Charging Temperature Range-5°C – 55 °C
Certification NumberSGSNA/21/SUW00045X

Frequently asked questions

What battery type is approved for use with the Tab-Ex® 03 D2?

Only the Samsung EB-BT575BBE battery pack is approved for use.

Can the device be charged in a hazardous location?

No, charging is only allowed in non-hazardous locations within the temperature range of -5°C to 55°C.

What are the ambient temperature limits for the device?

The ambient temperature must be between -20°C and +55°C.

Who can perform repairs on the device?

Repairs must be conducted by the manufacturer or an authorized service center.