This document describes the technical data, electrical connection, and curves of UC500-L2-E5-V15-Y259645 LED, including dimensions, electrical specifications, and response curves of the sensor.
This datasheet provides technical specifications and mechanical dimensions for the Pepperl+Fuchs UC500-L2-E5-V15 ultrasonic sensor. Key electrical data includes an operating voltage of 10 to 30 V DC, a sensing range from 35 mm to 500 mm, and a transducer frequency of approximately 380 kHz. This manual is written in German.
| Sensing range | 35 ... 500 mm |
|---|---|
| Adjustment range | 50 ... 500 mm |
| Dead band | 0 ... 35 mm |
| Transducer frequency | approx. 380 kHz |
| Response delay | <= 35 ms |
| Standard target plate | 100 mm x 100 mm |
| Mass | 115 g |
The factory setting is n = 5, where n is the number of sensors.
The sensor operates in an ambient temperature range from -25 to 70 °C (-13 ... 158 °F).
The connection type has a degree of protection of IP67.