This document introduces the Chart Recorder and Alarm Interface, one of the accessory cards that can be used with the PM100 and PM300 Power Analyzers to enhance their capability and flexibility. Each card in the range is a fully integrated, self-contained unit, driven by its own processor, which also communicates with the main instrument. This intelligent inter-processor communication allows the Power Analyzer to check when an accessory has been fitted, making it very easy for you to install. Simply plug in the card, switch on, and the Power Analyzer will recognise which accessory has been fitted and will configure the front panel menu accordingly.
This manual describes the Chart Recorder and Alarm Interface for Voltech PM100 and PM300 power analyzers. It includes 12 analog outputs for chart recorders and two relay outputs for alarm and demand functions. The interface is plug-and-play, automatically configuring the main analyzer upon installation. Outputs can be programmed to correspond to measured parameters, with voltage ranges from 0 to 5V. Relay contacts can be set to trigger on alarm thresholds or demand levels, with configurable normal open or closed states.
| Number of outputs | 12 |
|---|---|
| Output voltage range | 0V to 5V |
| Accuracy | 1% typical |
| Output resistance | <100Ω |
| Response time | 500msec typical |
| Connector | 15-way, ‘D’-type female |
Parameters include Vrms, Arms, W, VA, VAr, Power Factor, Frequency, V or A peak, V or A THD, and harmonic values.
Each output has a voltage range of 0 to 5V.
The interface has 12 analog outputs.