This manual provides detailed instructions for operating the UNI-T UT61A/61B/61C/61D/61E multimeters, including safety precautions, measurement procedures, and maintenance steps. It covers voltage, current, resistance, continuity, diode, capacitance, frequency, and temperature measurements. The manual also explains how to replace the battery and fuses, and includes specifications for each model variant. Safety warnings and international electrical symbols are emphasized to ensure safe usage.

What's inside

  • Unpacking Inspection
  • Safety Information
  • Rules For Safe Operation
  • The Meter Structure
  • Measurement Operation
  • Maintenance
  • Replacing the Battery
  • Replacing the Fuses
  • General Specifications

Specifications

Maximum Voltage Between Terminals and GroundingRefer to the different ranges input protection voltage
Fused Protection for mA Input Terminal1A H 240V 6x25mm
Display Maximum ReadingUT61A and UT61B: 4000, UT61C and UT61D: 6000, UT61E: 22000
Measurement SpeedUpdates 2~3 times/second

Frequently asked questions

How do I replace the battery in the multimeter?

Turn off the meter, remove the tilt stand and battery compartment, remove the old battery, insert a new 9V battery, and reassemble the parts.

What fuses are required for the multimeter?

For mA range: F1, 1A H 240V, 6x25mm (CE); for 10A range: F2, 10A H 240V, 6x25mm (CE).