This manual introduces the use of UT61A/61B/61C/61D/61E multimeters.
This manual provides detailed instructions for operating the UNI-T UT61A/61B/61C/61D/61E multimeters, including safety precautions, measurement procedures, and maintenance steps. It covers voltage, current, resistance, continuity, diode, capacitance, frequency, and temperature measurements. The manual also explains how to replace the battery and fuses, and includes specifications for each model variant. Safety warnings and international electrical symbols are emphasized to ensure safe usage.
| Maximum Voltage Between Terminals and Grounding | Refer to the different ranges input protection voltage |
|---|---|
| Fused Protection for mA Input Terminal | 1A H 240V 6x25mm |
| Display Maximum Reading | UT61A and UT61B: 4000, UT61C and UT61D: 6000, UT61E: 22000 |
| Measurement Speed | Updates 2~3 times/second |
Turn off the meter, remove the tilt stand and battery compartment, remove the old battery, insert a new 9V battery, and reassemble the parts.
For mA range: F1, 1A H 240V, 6x25mm (CE); for 10A range: F2, 10A H 240V, 6x25mm (CE).