TLAserX22/3xx, TLAser400 Laser Scan Micrometers & interface card (122/222/122s, 312, 330, 400) Operator’s Manual
This manual provides step-by-step instructions for operating and maintaining LaserLinc’s laser scan micrometers, including models TLAser122, TLAser222, TLAser122s, Triton312, Triton330, and TLAser400. It covers mounting, cabling, air purge use, cleaning procedures, and troubleshooting common issues. Safety precautions for laser exposure are included, along with technical specifications for each model. The manual also details preventive maintenance and how to resolve measurement errors such as 'Too Few' or 'Too Many' readings.
| Measurement range | .003” - .85” (.075mm – 22mm) |
|---|---|
| Resolution | .000001” (.025µm) |
| Two-second measurement repeatability | ± .000005” (± .125µm) |
| Single scan measurement repeatability | ± .0001” (± 2.5µm) |
| Accuracy | .00002” ± .01% of the maximum measurement size |
| Scan Rate | 400 scans / second |
| Ambient Temp. | 45F-110F |
| Power requirements from PC | +12VDC 125mA, +5VDC 100mA, -5VDC 75mA |
| Laser Class | Class II |
| Laser wavelength | 675nm |
| Weight | 2.6 lbs. (1.2kg) |
| Dimensions | 10”L x 1.25”W x 4”H |
Check that the part is in the field and illuminated by the laser. Check each axis via the test port for correct waveform.
Check that the scanner is powered and the data cable is connected to both the scanner and the TLAser400.