This manual introduces TOYO PBUS66-Z communication protocol for VF66B inverter.
This manual details the PROFIBUS-DP communication protocol for the PBUS66-Z optional circuit board, designed for Toyo VF66B inverters. It covers safety precautions, terminal specifications, communication modes, and data frames for PROFIDRIVE-compatible and original modes. The document also includes wiring and operation guidelines to ensure safe and correct use.
The PBUS66-Z enables remote control and monitoring of the VF66B inverter via PROFIBUS-DP, including speed, torque commands, and diagnostic data. It supports both PROFIDRIVE Profile 3.072 and custom modes, with detailed specifications for transmission speeds, cable types, and station configurations.
| Communication Protocol | PROFIBUS-DP compliant (EN 50170, IEC61158) |
|---|---|
| Physical Layer | RS-485 compliant |
| Connection Type | Bus type |
| Max Stations (without repeater) | 32 |
| Max Stations (with repeater) | 126 |
| GSD File | TOYO0BE7.GSD |
It uses PROFIBUS-DP compliant with EN 50170 and IEC61158 standards.
Up to 32 stations without a repeater, and up to 126 with a repeater.
The GSD file is TOYO0BE7.GSD.