This manual mainly introduces the product's usage methods and operating precautions.
This user manual provides detailed instructions for operating and installing the Samwontech ABM-2414 Series Analog Input Module. It covers safety precautions, control keys, parameter settings for input, control, alarm, and communication groups, wiring specifications, and troubleshooting. The manual also includes guidelines for proper installation environment, grounding, and handling of inductive loads to prevent damage or malfunction. Safety warnings and warranty terms are clearly outlined to ensure safe and correct usage.
| Input Sensor Types | TC.K1, TC.K2, TC.J, TC.E, TC.T, TC.R, TC.B, TC.S, TC.L, TC.N, TC.U, TC.W, TC.PL, TC.C, RTD PTA, RTD PTB, RTD PTC, JPTA, JPTB, DCV, 5V, 10V, mV |
|---|---|
| Operating Temperature | 10℃ ~ 50℃ |
| Power Supply | 100-240VAC, 50/60Hz, 10VAmax |
| Warranty Period | One year after end user buy it |
Ensure no one can accidentally touch terminals, avoid corrosive gases, minimal temperature fluctuations, no direct heat radiation, no water splashes, and no flammable materials nearby. Also, keep the device in a Pollution Degree 2 environment and Installation Category II.
Press SET/ENT Key to select input group after pressing ▲ or ▼ Key. Refer to Table 1 to select sensor type (e.g., TC.K1, TC.K2, etc.) and set parameters like high/low limits, decimal position, and bias range.
Insert a CR filter (for AC) or diode (for DC) in parallel as a surge-suppressor circuit to prevent sparks and damage. Recommended filters include BSE104R120, HN2EAC, CR UNIT 953, SKV, CR-CFS, etc.