REED Instruments Model 8778 Heat Stress Meter Instruction Manual

This manual introduces the features, specifications, and operating instructions of the REED Instruments Model 8778 Heat Stress Meter.


REED Instruments Model 8778 Heat Stress Meter Instruction Manual - cover page
Brand
Reed Instruments
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
10
File format
PDF
File size
1013 KB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
487E03C25C5E373FB94430992CB95962

About this manual

The REED Instruments Model 8778 Heat Stress Meter is a handheld device designed to measure environmental heat stress. It calculates the Wet Bulb Globe Temperature (WBGT) by measuring air temperature, black globe temperature, and relative humidity. The meter features an adjustable audible alarm, auto power-off, and interfaces for data logging via RS232 or USB.

What's inside

  • Features
  • Specifications
  • Instrument Description
  • Operating Instructions
  • Alarm Setting
  • Auto Power Off
  • Calibration
  • Troubleshooting
  • RS232 Interface
  • Battery Replacement

Specifications

Air Temp. Range0.0 to 50.0°C (32 to 122°F)
Air Temp. Accuracy±0.6°C (±1.1°F)
Black Globe Temp. Range0.0 to 80.0°C (32 to 176°F)
Humidity Range0 to 100% RH
Humidity Accuracy±3% RH: 10 to 90% RH, ±5% RH: rest of range
Power Supply2 x AAA batteries
Power Consumption1000 hours (Alkaline), 250 hours (General purpose)
Dimensions10 x 1.9 x 1.1” (254 x 49 x 30mm)

Frequently asked questions

What is the alarm threshold range?

The alarm threshold setting range is 20.0 – 37.2°C (68 - 99.0°F).

How long does the auto power off function last?

The meter automatically powers itself OFF after 20 minutes of inactivity.

How long does the calibration process take?

The calibration process will finish in approximately 60 minutes.

What are the RS232 interface settings?

The protocol is 9600 bps, 8 data bits, no parity.