Newport Corporation LTA Series Precision Long-Travel & High-Speed Motorized Actuators Service Manual

This manual provides detailed specifications, safety precautions, operating and maintenance procedures for the LTA series Precision Long-Travel & High-Speed Motorized Actuators.


Newport Corporation LTA Series Precision Long-Travel & High-Speed Motorized Actuators Service Manual - cover page
Brand
Newport Corporation
Category
Industrial Robot
Document type
Service Manual
Language
English
Pages
34
File format
PDF
File size
3.6 MB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
5116D0CE3C4F151FE9F9B57D166E1B95

About this manual

This service manual provides detailed instructions for operating, maintaining, and repairing Newport Corporation's LTA Series motorized actuators. It includes warranty information, mechanical specifications, drive options, connection guidelines, and safety warnings. The document also covers maintenance procedures, calibration, and handling precautions for different models within the LTA series, including LTA-HS, LTA-HL, and vacuum-compatible variants. Safety cautions address electrical hazards, environmental conditions, and proper handling to prevent damage or injury.

What's inside

  • Warranty
  • EC Declaration of Conformity
  • Definitions and Symbols
  • Warnings and Cautions
  • Introduction
  • Description
  • Characteristics
  • Drives and Motors
  • Connection to Newport Controllers
  • Connection to Non-Newport Electronics

Specifications

Travel50 mm (LTA-HS), 25 mm (LTA-HL)
Minimum Incremental Motion0.1 µm (LTA-HS), 0.05 µm (LTA-HL)
Repeatability±0.10 µm (typical), ±0.25 µm (guaranteed)
Maximum Speed5 mm/s (LTA-HS), 1 mm/s (LTA-HL)
Axial Load Capacity–50 N to +40 N (LTA-HS), –120 N to +100 N (LTA-HL)

Frequently asked questions

What is the warranty period for the LTA Series actuators?

Newport Corporation warrants this product to be free from defects in material and workmanship for a period of 1 year from the date of shipment.

What are the maximum speeds for the LTA-HS and LTA-HL models?

The maximum speed for LTA-HS is 5 mm/s, and for LTA-HL is 1 mm/s.

What is the minimum incremental motion for LTA-HS and LTA-HL models?

The minimum incremental motion for LTA-HS is 0.1 µm, and for LTA-HL is 0.05 µm.

What is the operating temperature range for the actuators?

The operating temperature range is +10 to +35 °C.