This is the instruction manual for Anderson HA Sanitary Electronic Pressure Transmitter
The Anderson HA Sanitary Electronic Pressure Transmitter converts process pressure into a standard 4-20 mA DC signal. It features 316L stainless steel wetted parts and is designed for sanitary applications where moisture protection is critical. The unit operates on 10-40 VDC loop power and includes non-interrupting circuit verification test points.
| Excitation | 10-40 VDC (Absolute), 24 VDC Nominal |
|---|---|
| Output | 4-20 mA DC, 2 wire |
| Accuracy | ±0.5% of Full Scale |
| Repeatability | ±0.3% of full scale |
| Wetted Parts | 316L stainless steel electropolished |
| Housing Material | 304 Stainless Steel |
Anderson recommends a 24 gauge, 4 conductor, shielded cable.
The sensor should be inspected at 6 month intervals.
A high current flow approaching 30 mA indicates an internal short.