Conduit IP67 Base Station Getting Started Guide provides a quick start guide for Conduit IP67 Base Station device, introduces the features and use methods of the device.
This guide introduces the Multi-Tech Conduit IP67 Base Station, a rugged IoT gateway for outdoor LoRa deployments. It covers installation, model-specific setup (mPower and mLinux), LoRa and AT command references, and hardware differences between V1.5 and V2.1 versions. The V2.1 design uses an Analog Devices RF front-end and FPGA-based architecture, supporting geolocation via GPS but requiring server-side upgrades for full compatibility.
| Model Numbers | MTCDTIP-xxx-266x-xxx, MTCDTIP-xxx-267x-xxx, MTCDTIP-xxx-270x-xxx, MTCDTIP-xxx-275x-xxx |
|---|---|
| V2.1 Hardware Change | Replaced custom Semtech RF front-end ASIC with Analog Devices AD9361 |
| V2.1 Geolocation Support | Supports geolocation via GPS PPS output |
| V2.1 Packet Compatibility | Not backward-compatible with V1.5 packet format |
Models MTCDTIP-xxx-266x-xxx, MTCDTIP-xxx-267x-xxx, MTCDTIP-xxx-270x-xxx, MTCDTIP-xxx-275x-xxx.
No, MultiTech’s server code has not been upgraded to handle V2.1 packets, so it can only be used as a packet forwarder without server-side support.