Moxa EDS-305 Ethernet Switch Hardware Installation Guide

Moxa EDS-305 is a smart Ethernet switch that provides an economical solution for your Ethernet connections. It has a built-in smart alarm function that helps system maintainers monitor the health of your Ethernet network. The EDS-305 has a wide operating temperature range of -40 to 75°C, and is designed to withstand a high degree of vibration and shock. The rugged hardware design makes either model perfect for ensuring that your Ethernet equipment can withstand critical industrial applications, and complies with FCC and CE Standards.


Moxa EDS-305 Ethernet Switch Hardware Installation Guide - cover page
Brand
moxa
Category
Industrial Robot
Document type
Installation Guide
Language
English
Pages
16
File format
PDF
File size
428 KB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
31A365BEDFC02CF755C9CA9AC5D3EEB8

About this manual

The Moxa EDS-305 is a smart Ethernet switch designed for industrial applications, featuring a rugged design with a wide operating temperature range of -40 to 75°C for extended models. It supports 10/100BaseT(X) and 100BaseFX interfaces and includes built-in smart alarm functions to monitor network health.

What's inside

  • Overview
  • Package Checklist
  • Features
  • Panel Layout
  • Mounting Dimensions
  • DIN-Rail Mounting
  • Wall Mounting
  • Wiring Requirements
  • Grounding
  • Wiring the Alarm Contact

Specifications

Operating Temperature (Standard)0 to 60°C
Operating Temperature (Extended)-40 to 75°C
Interfaces10/100BaseT(X), 100BaseFX
Switching ProcessStore and Forward
Address Entries1024
Power Input12 to 48 VDC
Max Power Current0.6A
Min Power Current1.1A

Frequently asked questions

What is the operating temperature range for standard EDS-305 models?

The standard operating temperature range is from 0 to 60°C.

What is the operating temperature range for extended EDS-305 models?

Extended models have an operating temperature range from -40 to 75°C.

What voltage and current ratings are required for the power supply?

The power supply must be rated to deliver 12 to 48 VDC at a maximum of 0.6A.

What happens when the Fault LED lights up?

The Fault LED lights up when the corresponding PORT alarm is enabled and the port's link is inactive.