This document is an operation and service manual for EZ3 series SCR power controllers. It introduces the basic functions and features of the controller, as well as the wiring method, start-up procedure, etc.
This manual provides detailed instructions for operating and servicing Phasetronics EZ3 SCR power controllers, covering manual and automatic control setups, wiring, specifications, and start-up procedures. It includes information on mounting, power connections, jumper settings, and replacement parts for various amp ratings. The manual also addresses safety precautions and warranty terms.
| Output Voltage | 0 to 100% |
|---|---|
| AC Supply Voltage | 120/208/240/380/415/480/575 Vac (+10% to -15%, 50/60 Hz) |
| Ambient Temperature | 0 to 40 degrees C (32 degrees F to 104 deg. F) |
| SCR Peak Inverse Voltage (PIV Rating) | 1600V for units up to 100A, 1800V for units 150A to 1000A |
| Cooling | Convection cooling through 150A. Fan cooled at 225A and above. |
The output voltage range is 0 to 100%.
Supported AC supply voltages are 120/208/240/380/415/480/575 Vac (+10% to -15%, 50/60 Hz).
The ambient temperature operating range is 0 to 40 degrees C (32 degrees F to 104 deg. F).
Units up to 100A have a PIV rating of 1600V, and units from 150A to 1000A have a PIV rating of 1800V.