Phasetronics EZ1 10 to 1000A SCR Power Controller Operation and Service Manual

This manual describes the operation and maintenance of Phasetronics EZ1 Series SCR Power Controllers (10 to 1000 Amps). The series controllers are low-cost microprocessor-based controllers that utilize a rapid-cycle control technique that can extend the life of industrial resistance heaters.


Phasetronics EZ1 10 to 1000A SCR Power Controller Operation and Service Manual - cover page
Brand
Phasetronics
Document type
Service Manual
Language
English
Pages
18
File format
PDF
File size
1.6 MB
Published
19 October, 2023
Updated
19 October, 2023
Model
EZ1
MD5 checksum
86B07D111B8E1DED54A59F8D9433C244

About this manual

This manual provides detailed instructions for operating and servicing Phasetronics EZ1 10 to 1000A SCR power controllers. It covers installation, wiring diagrams, manual and automatic control setups, power connections, and specifications. The controller uses zero voltage switching technology for RFI-free operation and features variable time proportioning for precise heating control. Safety warnings and warranty information are also included.

The manual includes sections on mounting, wiring, control inputs (manual potentiometer or 4-20mA/0-5mA/10-50mA/0-10V signals), output voltage control, cooling methods, and protective networks. It also details replacement parts, model selection guides, and jumper configurations for different voltage and time base settings.

What's inside

  • Introduction
  • Specifications
  • Connections
  • Start-up Procedure
  • Dimensions
  • Appendix: Connectors, Jumpers, Test Points, Replacement Parts, Model Selection Guide
  • Warranty Information

Specifications

Output Voltage0 to 100%
AC Supply Voltage120/208/240/380/415/480/575 Vac (+10% to -15%, 50/60 Hz)
Type of LoadsResistive Only
SCR Peak Inverse Voltage (PIV Rating)1600V (up to 100A), 1800V (150A to 1000A)
Cooling MethodConvection cooling thru 150A. Fan cooled at 225 A and above.
Ambient Temperature0 to 40 degrees C (32 degrees F to 104 deg. F)
Output Time BaseSelectable: 16 steps or 64 steps

Frequently asked questions

What is the output voltage range of the EZ1 controller?

The output voltage range is 0 to 100%.

What types of loads can the EZ1 controller handle?

The EZ1 controller is designed for resistive loads only.

What is the cooling method for the EZ1 controller?

The controller uses convection cooling up to 150A, and fan cooling for 225A and above.

What is the ambient temperature operating range?

The operating range is 0 to 40 degrees C (32 degrees F to 104 deg. F).

Download PDF (1.6 MB)

More Phasetronics Manuals


View all Phasetronics manuals →